15mm sensing on M30 threads, with 10V–30V supply limits and -25°C to 70°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NO |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Does 15mm reach justify the M30 mounting hole?
15mm is the listed sensing distance. It makes E2E-X15C130 5M a candidate where a target passes close to a fixed machine position, but it does not prove detection at that distance for the intended target. The M30 threaded cylinder sets the other early decision: if the mounting hole cannot take it, the electrical specifications won't rescue the fit, even with a compatible controller input.
Active lifecycle status supports new design-in rather than limiting the sensor to sustaining work. The NPN-NO, 3-wire output must suit the controller input; a mismatch can leave a sound mechanical installation unable to signal a target. Treat the 250Hz response-frequency figure as a ceiling to check against target events, not a promise that every passing target will be detected.
Where do temperature and supply limits stop the fit?
-25°C to 70°C is the listed operating-temperature range. A position outside it rules out the installation regardless of the IP67 and IP69K ingress ratings. The 10V to 30V supply limits bound the permitted rail, but they do not specify output drive capability or settle the input-circuit design.
The shielded inductive sensor has a nickel-plated brass body and needs a fixed industrial mounting point. Its ingress ratings do not settle whether the cable exit suits the installation.
What still blocks a final sensor drawing?
The missing wiring diagram is the weak point, even though the NPN-NO output is stated. The datasheet still needs to supply that diagram, a mounting drawing and sensing-distance information for the intended target. Until then, the control drawing and detection position remain open.
Will the cable leads match the running line?
Will the cable leads fit the line’s harness? E2E-X15C130 5M has cable leads and an M30 threaded body; match both to the installed harness and mount before purchasing for existing production. A box package does not change the termination. The lifecycle fields agree on Active status, and EU RoHS compliance is listed, so neither creates a stated obstacle to new design-in. The buying risk is getting the right sensor function with the wrong physical connection for the line.
View the Win-Source product page for E2E-X15C130 5M.
Key Takeaways for Engineers & Buyers
- Check the 15mm sensing distance against the intended target position.
- Match the input circuit to the NPN-NO, 3-wire output.
- Check that cable leads suit the existing harness.