15mm sensing, 10V–30V supply, M30 threaded body and NPN-NC cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Is the Active sensor a sensible new-design choice?
Can I still specify this sensor for a new machine? Yes. Omron lists E2E-X15C230 5M as Active across its lifecycle fields, with no conflicting end-of-life signal. New design-in is reasonable. EU RoHS is listed as compliant.
The purchase constraint is the termination. This version has cable leads, not a stated connector. Put that on the build documentation so a connector expectation doesn't stall installation.
The M30 body fits metalwork, but the output must match
Cable leads put termination work at the machine rather than at a stated connector, but the M30 threaded, shielded inductive body fits an installation that calls for that mounting style. The nickel-plated brass body carries IP67 and IP69K ingress ratings; neither rating establishes how the finished cable termination is sealed.
The NPN-NC, 3-Wire output cannot connect directly to a controller input expecting a different polarity without an interface change. The listed 15mm sensing distance is a starting point for target spacing, not a guaranteed trigger gap for every target material.
The supply range and response frequency set different limits
The 10V–30V supply range limits the control rail: a controller outside it is not an electrical fit. A rail inside that range still doesn't establish output-load compatibility. The -40°C to 85°C operating-temperature range bounds the stated environment; operation beyond either endpoint falls outside it.
The listed 250Hz response frequency matters for moving-target detection, not supply or load capacity. It does not prove the sensor will catch a particular target passing through the sensing zone. Target geometry and timing still matter.
A 15mm distance does not close the mounting details
15mm is the listed sensing distance, but the target-material sensing curve is absent, leaving the actual trigger gap unsettled. The cable-lead wiring diagram and M30 outline drawing are also absent; final wiring and mounting dimensions remain open.
View the Win-Source product page for E2E-X15C230 5M.
Key Takeaways for Engineers & Buyers
- Match the 10V–30V supply range to the control rail.
- Check the controller input against the NPN-NC, 3-Wire output.
- Reserve an M30 mounting position and a route for the cable leads.