15mm inductive sensing, 10V ~ 30V supply bounds and a threaded M30 body with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Can the active E2E-X15C230-R 2M go into a new machine?
Can it go into a new machine build? Yes. Both lifecycle fields read Active, with no conflict listed. Active doesn't settle controller compatibility: the 3-wire NPN-NC output needs a matching input, and wiring alone will not adapt a different signal.
The part is listed as EU RoHS compliant, with no revision stated. That status does not settle the mechanical or electrical fit of the build.
The 15mm reach sets the fixture before the rail does
Target spacing constrains the fixture. The listed 15mm sensing distance provides a reference, but it does not establish detection of every target at that distance; target-dependent performance still needs the sensor documentation. The threaded M30 body and shielded construction point to a mounted industrial installation, not a small-board sensing position.
The 10V ~ 30V supply listing bounds the rail choice. Treat 30V as a ceiling, not a working setpoint; a rail below 10V falls outside the stated bounds. The -25°C ~ 70°C operating-temperature range rules out locations beyond its ends. IP67 and IP69K are listed ingress ratings, but neither resolves how the cable entry behaves in the finished machine.
Cable leads, not a connector, set the build task
3-wire NPN-NC output comes through cable leads, not a mating connector. Box describes the packaging. Route and terminate the leads as part of the machine build.
What the 250Hz rating cannot settle
The pinout is absent. The 250Hz response-frequency rating still provides a ceiling for judging whether a detection task is in range, but it does not specify the switching waveform or edge timing seen by a controller input. Those gaps matter when the input filter must distinguish a passing target from a missed event.
The output load-current limit and mounting drawing are absent too. Obtain both before assigning the input load or fixing the M30 installation clearance; neither decision follows from sensing distance alone.
View the Win-Source product page for E2E-X15C230-R 2M.
Key Takeaways for Engineers & Buyers
- Set the target position against the listed 15mm sensing distance.
- Keep the sensor supply within the listed 10V ~ 30V bounds.
- Match the controller input to the 3-wire NPN-NC output.