15mm sensing limit, 10V–30V supply limits, threaded M30 body and NPN-NC cable-lead output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Can this sensor go on a new machine BOM?
Can we put this on a new machine BOM? Both lifecycle and product status list E2E-X15C230-R 5M as Active, with no conflict, so it remains a reasonable choice for new design-in and existing production. It is marked EU RoHS compliant.
Put the cable-lead termination method on the assembly drawing. Assuming a connector will stop the build at wiring.
NPN-NC logic rules out the wrong controller input
Wrong for a PNP input or a normally open channel. E2E-X15C230-R 5M has a 3-Wire NPN-NC output. An input expecting the opposite output type or contact state will receive the wrong signal, not merely a shorter sensing range.
The threaded M30 cylinder suits a machine-mounted sensing point with a route for its cable leads. Its shielded construction and IP67, IP69K ratings support consideration where ingress matters, but those ratings do not establish how the cable termination is sealed.
The 15mm gap and 250Hz ceiling need separate checks
These limits stand apart. The 15mm sensing-distance figure is a ceiling for the target gap under the specified sensing conditions, not a promise that every metal target trips the sensor at that distance. The 250Hz response-frequency ceiling sets the event rate worth evaluating; it does not establish reliable detection of a moving target in the installed geometry.
The 10V and 30V supply limits bound the sensor supply rather than settling controller-input compatibility. The -25°C to 70°C operating-temperature range excludes mounting points outside that span, regardless of the ingress ratings. A small target moving past the sensing face is the trap: the listed distance and frequency are separate limits, not a combined detection guarantee.
Pinout and mounting details still hold up release
And the installation still isn’t settled. Without a pinout, the NPN-NC wiring cannot be released from this page; without a mounting drawing, bracket clearance remains unresolved. The output load-current limit is also absent, leaving the controller interface open.
View the Win-Source product page for E2E-X15C230-R 5M.
Key Takeaways for Engineers & Buyers
- Test the actual target against the listed 15mm sensing limit.
- Check the machine event rate against the 250Hz response ceiling.
- Match the 3-Wire NPN-NC cable leads to the controller input.