15mm sensing, 10V ~ 30V supply, M30 thread, -25°C ~ 70°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NC |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new E2E-X15C2L30 2M installation
NPN-NC output limits controller choice. Still, E2E-X15C2L30 2M suits new design-in when that logic is specified: all listed lifecycle signals agree on Active. EU RoHS compliance is listed.
Supply bounds and sensing reach decide placement
Supply compatibility comes first: the 10V ~ 30V range rules out a controller supply outside those bounds but says nothing about output-load capability. The -25°C ~ 70°C operating range gives the listed ambient limits, not a guarantee that an installation will stay within them.
The listed 15mm sensing distance is a starting point for target placement, not a detection margin for the intended workpiece. Positioning a bracket on that number alone could leave a moving target undetected.
250Hz sets the event-rate screen; cable leads set the build
250Hz is the listed response-frequency ceiling. A faster event stream falls outside that rating, and the number doesn't specify the shortest detectable target passage.
For a running line, cable-lead termination is a practical purchasing constraint. Specify that termination in the build instruction for E2E-X15C2L30 2M rather than assuming a plug-in connection. Box describes the packing, not the electrical connection.
An NPN mismatch rules this sensor out before ingress does
A controller input expecting a sourcing output is the wrong destination for this NPN-NC, 3-Wire sensor. With a compatible input, a shielded M30 threaded installation is the better fit; the listed IP67 and IP69K ingress grades help define where the enclosure can be considered, but say nothing about switching behavior at the target.
Lead assignment still needs a wiring diagram, and bracket clearance needs a mechanical drawing. An output-load rating is absent, leaving electrical input compatibility open even when the logic matches. A target-dependent sensing curve is absent too: the listed 15mm distance alone cannot establish detection at the chosen workpiece.
View the Win-Source product page for E2E-X15C2L30 2M.
Key Takeaways for Engineers & Buyers
- Check the intended target against the listed 15mm sensing distance.
- Match the controller input to NPN-NC, 3-Wire output.
- Get the M30 mechanical drawing before fixing the bracket.