15mm sensing distance, 10V ~ 30V supply, M30 body, and -40°C ~ 85°C operating range
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 250Hz; Voltage - Supply: 10V ~ 30V |
15mm reach makes this an active design-in candidate
15mm is the listed sensing distance, not a promise for every metal target. Where the target position supports that reach, E2E-X15C330 2M is a candidate for new designs: lifecycle and product status both say Active. It is EU RoHS compliant.
The M30 body fits a cabled NPN machine input
An input that needs a connector, or switching above the listed 250Hz response-frequency ceiling, rules this sensor out. It suits a machine input built for NPN-NC/NO, 3-Wire signaling, while its shielded M30 threaded body sets the mounting approach and its cable leads determine the connection to the controller.
The 10V ~ 30V supply range bounds the rail choice; neither end permits operation outside that range. The -40°C ~ 85°C operating-temperature range defines the stated environmental window, not performance beyond it. Get either boundary wrong and the installation falls outside the listed conditions, even if the sensor switches on a bench.
Ingress ratings help; detection details remain open
What isn't specified matters here: without an output load-current limit or cable-lead wiring assignments, PLC input loading and termination remain unresolved. IP67 and IP69K ingress ratings and a nickel-plated brass body give a concrete reason to consider the sensor near wet equipment. They do not replace a dimensional drawing or target-material sensing curves; those missing details determine whether the installed mount and target will produce dependable detection.
Keep the cable-lead build consistent on the line
And ingress protection won't prevent an assembly mistake at the cable end. Box packaging and cable-lead termination make this a cabled build, not a connector swap. Put termination and routing into the work instructions before releasing the sensor to existing production; a changed cable connection can stop a line even when the sensing position is right.
View the Win-Source product page for E2E-X15C330 2M.
Key Takeaways for Engineers & Buyers
- Match the machine input to the NPN-NC/NO, 3-Wire output.
- Keep the supply within 10V ~ 30V.
- Set the M30 mounting position against the 15mm sensing distance.