Omron E2E-X15D1-T 2M: Active, but RoHS needs resolution

E2E-X15D1-T 2M Omron product image

15mm inductive sensing, 250Hz response ceiling, M30 threaded body; RoHS fields conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 15MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 250Hz; Voltage - Supply: 12V ~ 24V

Can this Omron sensor enter a new build?

Can this go into a new machine build? On lifecycle grounds, yes: both lifecycle and product-status fields mark E2E-X15D1-T 2M Active, so neither limits it to sustaining designs. Compliance is the stop sign. One field says RoHS Compliant; the specifications say RoHS Non-Compliant. Those conflicting fields cannot establish compliance, so hold release for any build requiring EU RoHS until the conflict is resolved.

The intended job is inductive detection from an M30 threaded cylinder with a listed 15mm sensing distance. That distance helps set the sensor’s position relative to the target, but it does not establish detection at 15mm for every target and mounting arrangement, so the actual machine geometry still needs a fit check.

Will 15mm reach and 250Hz response fit the machine?

Even if the compliance conflict is cleared, the 250Hz response frequency remains a ceiling, not a guaranteed detection rate for every passing target. A machine whose target events demand more than that ceiling needs a different sensing plan. The shielded inductive construction belongs where the target passes a fixed sensing face; the listed 15mm distance is no reason to place that face farther away.

The operating-temperature range is -25°C to 70°C. It sets the stated environmental bounds for the installation, not the temperature of the mounting point once the machine is running.

The M30 body commits the mounting and wiring

The M30 thread dictates the mount. An existing bracket without room for that cylinder is not rescued by the 15mm sensing distance. The output is normally open and 2-wire, with cable leads rather than a connector; match the receiving circuit and cable route to those features before committing the machine layout.

Bulk packaging makes assembly handling a build consideration. Put the M30 mount and cable-lead termination on the build instructions so a running line doesn’t discover a mechanical or wiring mismatch at installation.

What the 12V to 24V supply range cannot settle

24V is the upper end of the listed 12V to 24V supply range, not an output-load limit. No output-load rating or wiring diagram is listed, leaving the receiving-circuit check open. A dimensioned mounting drawing is also absent; bracket clearance and sensing-face placement remain unsettled without it.

View the Win-Source product page for E2E-X15D1-T 2M.

Key Takeaways for Engineers & Buyers

  • Hold E2E-X15D1-T 2M release until the RoHS conflict is resolved.
  • Check the 250Hz response ceiling against the target rate.
  • Reserve an M30 threaded mount and route the cable leads.