15mm sensing distance, 12V ~ 24V supply bounds, and an M30 threaded body set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 250Hz; Voltage - Supply: 12V ~ 24V |
The RoHS conflict can stop this Active sensor at release
The 250Hz response-frequency ceiling limits target-event speed, but the RoHS conflict could stop release even in a slower machine. Omron E2E-X15D1-T 5M remains a conditional new-design choice rather than a sustaining-only part: all lifecycle signals agree on Active, yet the compliance field says RoHS Compliant and the specifications say RoHS Non-Compliant. Neither entry establishes whether a build requiring EU RoHS can use the sensor. Obtain a part-specific compliance determination before release.
The supply bounds and temperature range narrow the installation
12V ~ 24V is the listed supply range. A rail outside those bounds rules the sensor out, but the range says nothing about the load its output can drive. The -25°C ~ 70°C operating-temperature range bounds the installation, not the temperature the sensor will reach in a particular mount. The 250Hz response-frequency ceiling is no switching-delay specification; a fast sequence of targets still needs timing information before the control input can be settled.
Bulk packing puts cable handling on the assembly line
Will bulk packing and cable leads suit the line? Plan routing for loose, cable-led sensors before fixing the assembly process. Don’t assume a connector is included.
15mm reach still leaves the actual switching gap open
15mm is the listed sensing-distance ceiling, not a guaranteed switching gap for every target. The shielded inductive sensor suits a metal target where its threaded M30, nickel-plated brass body can be mounted and the cable leads routed; it does not fit a board-mounted sensor footprint. IP67 gives the ingress-protection rating, but leaves cable-entry protection in the assembled machine unresolved.
The sensing-distance test conditions and hysteresis are absent, so the usable switching gap remains open. Output load limits are absent too; the listing cannot settle interface current. Check bracket clearance around the threaded body against a mechanical drawing.
View the Win-Source product page for E2E-X15D1-T 5M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS entries before release.
- Keep target events within the 250Hz response-frequency ceiling.
- Check bracket clearance against the M30 body drawing.