10V–30V supply, 16mm sensing limit, M18 threaded body and PNP-NO cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM PNP M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An NPN-input station rules this sensor out
A connectorized or NPN-input station is the wrong place for this sensor. E2E-X16MB1D18-R 2M has a 3-wire PNP-NO output and cable leads; it belongs on an input wired for that output, not one expecting the opposite polarity. All listed lifecycle signals read Active, supporting new design-in without a lifecycle-driven reason to migrate existing production. It is EU RoHS compliant.
Will the M18 body and cable leads fit the existing station?
Will it fit the station already on the machine? The M18 threaded cylinder may match a threaded sensor position, but the thread alone doesn't establish body clearance. The listed 16mm sensing distance is a reach limit, not a guaranteed trigger point for every metal target and mounting arrangement; set pickup position with target-specific data.
Cable leads set the buying constraint. This isn't a connector-terminated sensor, and box packaging does not remove the harness work. On an existing production line, match the cable termination to machine wiring before ordering E2E-X16MB1D18-R 2M; a harness mismatch stops the station even if the M18 thread fits. The listed IP67 and IP69K ingress ratings do not establish clearance around an unshielded sensing face.
The supply and response limits bound the installation
Supply and response limits constrain the installation. The 10V to 30V range bounds the rail choice: 30V is the listed upper limit, not a target voltage, and a rail outside the range is not covered here. The 400Hz response-frequency figure is a ceiling, not proof that every passing target will register. On a moving line, a missed transition becomes a missed detection.
The listed operating-temperature range is -40°C to 85°C. It covers the proposed ambient only within those endpoints; it does not establish how mounting or electrical loading affects the sensor at the hot end.
The missing drawings and output limit still matter
That still leaves four concrete gaps: the output-current limit, target-material correction curve, mounting-clearance drawing and lead pinout are not listed. The current limit determines whether the PNP output can drive its assigned input; the drawing determines whether the unshielded M18 body fits as planned.
View the Win-Source product page for E2E-X16MB1D18-R 2M.
Key Takeaways for Engineers & Buyers
- Match the 3-wire PNP-NO output to the machine input.
- Check the target position against the 16mm sensing limit.
- Obtain the output-current limit before assigning the input load.