16mm sensing, 10V to 30V supply, M18 body; unshielded PNP-NO with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM PNP M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the lifecycle question, not the mount
The unshielded body makes a crowded metal mount harder to approve than the M18 thread alone suggests. Even so, Omron E2E-X16MB1T18 5M is a candidate for new design-in: Lifecycle Status and Product Status both say Active, with no stated conflict. The PNP-NO, 3-wire output gives the controls team a defined interface to assess. EU RoHS compliance is listed. None of that establishes where the sensor will switch against the machine’s actual target.
The 16mm reach is a screening limit, not a trip point
Reach isn’t a trip point. The listed 16mm sensing distance is a ceiling for screening, not a guaranteed switching point against every metal target; a machine that depends on the full distance needs target-specific evidence. The listed 10V lower and 30V upper supply boundaries rule out rails outside that range, but do not settle tolerance to supply disturbances. The stated operating-temperature range of -40°C to 85°C screens the installation environment; it does not establish sensing distance at either end of that range.
An unshielded M18 body leaves mounting questions open
That uncertainty carries through to the machine face, where E2E-X16MB1T18 5M must see the intended target without nearby metal changing the result. Its threaded M18 body suits a sensor bracket, but the unshielded construction makes bracket geometry part of the sensing decision. The listed 400Hz response frequency helps screen moving-target applications; it does not establish detection of a particular target at line speed.
A target-dependent sensing curve and mounting-clearance drawing are still needed. Without them, neither the 16mm claim nor the M18 thread settles placement. An output load-current limit and wiring diagram are also absent here; the stated PNP-NO, 3-wire output identifies the interface type, not the load it can drive or the connections to make.
Cable leads rule out a plug-in sensor swap
Wrong for a connectorized swap: this M18 sensor has cable leads. For a line already built around cable-lead sensors, put that termination on the BOM and match it to the machine harness before ordering. Active status can’t fix a termination mismatch on the line.
View the Win-Source product page for E2E-X16MB1T18 5M.
Key Takeaways for Engineers & Buyers
- Check the 16mm reach against the actual target and unshielded mounting.
- Keep the supply within the listed 10V to 30V boundaries.
- Match the 3-wire PNP-NO cable leads to the machine input.