16mm sensing distance, 10V ~ 30V supply, M18 body, and -40°C ~ 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM PNP M18 NO/NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
The 16mm reach makes this an active design-in candidate
16mm is the listed sensing distance, making E2E-X16MB3DL18 2M a candidate where a metal target passes close to the sensor face. It does not establish reliable detection at that distance for every target or mounting arrangement. The listed lifecycle fields all say Active, with no conflict shown, and EU RoHS compliance is listed. Test the sensing geometry first.
Supply and response limits set separate boundaries
The supply range sets the electrical boundary: 10V ~ 30V, with 30V as a ceiling even when the machine supply rises. A controller supply outside that range rules out a direct fit. The 400Hz response-frequency figure is also a ceiling, not a promise that every target passage will produce a usable controller event. Target motion and the input arrangement still govern timing. Neither figure establishes switching margins.
M18 buys a threaded mount, not a finished installation
M18 gives the mechanical drawing a starting point: a threaded cylindrical body, not a settled sensor-face position or mounting clearance. The sensor is unshielded, so mounting it as though nearby metal were irrelevant risks changing the detection behavior suggested by the 16mm figure. Its listed -40°C ~ 85°C operating range sets temperature bounds but doesn't settle the temperature at the sensing face in a particular machine.
Cable leads and target material decide the production fit
A nonmetal target rules this sensor out. Cable Leads also rule it out for an assembly expecting a connector-ended sensor. On industrial machinery where an inductive sensor can face a metal target, the PNP-NC/NO, 3-Wire output must match the controller input; put that choice on the wiring drawing, because a mismatch can turn a passing target into the wrong machine signal.
IP67 and IP69K are listed ingress ratings useful for wet machinery, but they don't describe the protection of the completed cable installation. The purchasing constraint is the lead termination, not a lifecycle warning. Specify Cable Leads on the order and retain the Box packaging designation so the received part matches the assembly instructions.
The missing drawings still control release
The listing lacks a pinout and mechanical drawing, though the 16mm reach and 400Hz response-frequency ceiling give the application check a starting point. The drawings are needed to finish wiring and place the M18 body. Target-dependent sensing information and switching timing detail are also missing, so those figures cannot close the check.
View the Win-Source product page for E2E-X16MB3DL18 2M.
Key Takeaways for Engineers & Buyers
- Check the 16mm reach against the actual metal target.
- Keep the sensor supply within 10V ~ 30V.
- Match the PNP-NC/NO, 3-Wire cable leads to the controller input.