16mm sensing distance, 10V ~ 30V supply, unshielded M18 body, -40°C ~ 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An unshielded M18 head needs the right mounting position
A flush-mounted sensing point is the wrong starting assumption for this unshielded M18 cylinder. Omron E2E-X16MC118 5M is Active and fits a new design that can accommodate unshielded mounting. Its NPN-NO, 3-Wire output must match the control input; extra reach won't fix a wiring mismatch.
The lifecycle signals agree on Active status. EU RoHS compliance is listed.
Cable leads are the production constraint
Can the existing line use cable leads? E2E-X16MC118 5M has that termination style and comes in a box; it is not listed with a connector termination. An assembly built around a plug-in sensor would need a wiring change even if its M18 mounting position worked. Specify cable leads on the BOM before committing the assembly.
The 16mm reach and 400Hz ceiling set different limits
Reach and target rate impose separate limits. The listed 16mm sensing distance is a reach to assess, not a promise that every metal target switches at that gap. Nearby metal matters to placement with an unshielded M18 body; the distance figure alone cannot settle a close-packed installation.
The 400Hz response frequency is a ceiling for assessing target rate, not a switching-delay specification; a target sequence beyond it has no support from that figure. The 10V ~ 30V supply range rules out rails outside those bounds, with 30V a ceiling rather than a working setpoint; the -40°C ~ 85°C operating-temperature range likewise bounds the stated environment without accounting for heating at the mounting point. None of these limits establishes how a particular target behaves at the edge of the sensing field.
Ingress ratings help, but do not settle washdown exposure
And that mounting point may be wet. IP67 and IP69K are listed ingress ratings, and the body is nickel-plated brass. Those ratings support considering the sensor for a wet industrial location, but do not establish resistance to the cleaning chemistry used there. The LED can show a local switching indication; it can't tell a technician whether the controller received the intended signal.
Mounting and switching details remain open
The listing stops short. Switching hysteresis, the output load-current limit, and an unshielded mounting-clearance drawing are absent. Those details bear on repeatability near the trip point, whether the output can drive the intended input, and how close adjacent metal can sit.
View the Win-Source product page for E2E-X16MC118 5M.
Key Takeaways for Engineers & Buyers
- Allow for an unshielded M18 mounting position.
- Match the controller input to the NPN-NO, 3-Wire output.
- Check target motion against the 400Hz response-frequency ceiling.