16mm sensing distance, 400Hz response ceiling, M18 thread, and cable leads set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
The unshielded M18 body needs the right mounting position
A flush-mounted or connectorized position is the wrong starting point for this unshielded M18 cylinder with cable leads. Omron E2E-X16MC118-R 2M is Active across the lifecycle fields, making it a reasonable new-design choice when the threaded industrial fixture permits an unshielded body and the machine has an NPN-NO, 3-Wire input. The listed 16mm sensing distance helps screen target spacing but cannot guarantee a trip point for every metal target. EU RoHS is reported compliant.
A 400Hz ceiling does not settle target detection
400Hz is the listed response-frequency ceiling. It can rule out a motion requirement beyond that rating, but it does not promise detection of every target passing at that rate; establish the actual detection window in the machine. The 10V ~ 30V supply listing sets the electrical boundaries, with 30V as the ceiling and 10V as the lower listed boundary. Neither figure establishes behavior outside that range.
The stated operating-temperature range is -40°C ~ 85°C. It helps screen the installation environment but does not establish sensing performance across the range. IP67 and IP69K address enclosure exposure, not whether the output will catch a brief target pass.
M18 fit and cable leads constrain the order
M18 fit sets the purchasing constraint. Keep E2E-X16MC118-R 2M on the BOM only when the threaded opening and cable-lead termination match the assembly; specify that connection when ordering the box-packaged part. Active status cannot resolve a harness mismatch.
The M18 installation still needs a drawing
The drawing is missing. No mounting drawing or unshielded installation clearances are listed, so the metal-bracket position remains unresolved despite the stated 16mm sensing distance. The cable-lead wiring diagram and output load-current limit are also missing; the NPN-NO label alone doesn't settle the connection or load budget.
View the Win-Source product page for E2E-X16MC118-R 2M.
Key Takeaways for Engineers & Buyers
- Check the target material and spacing against the listed 16mm sensing distance.
- Keep the supply within the listed 10V ~ 30V boundaries.
- Match the NPN-NO, 3-Wire output to the machine input.