16mm sensing distance, 10V ~ 30V supply, M18 body; NPN-NO cable output needs a matching input.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
An NPN-NO sensor is wrong for a PNP input
A PNP-input machine is the wrong place for this NPN-NO, 3-wire sensor. An unshielded M18 inductive station with a listed 16mm sensing distance is worth considering. Omron E2E-X16MC1L18 2M is Active and EU RoHS compliant; its lifecycle doesn't rule out new design-in.
The 16mm reach does not settle the trip point
Even then, the listed 16mm sensing distance does not settle mounting geometry: with an unshielded body, nearby metal and the actual target both bear on the trip point. It is not a guaranteed switching point in every fixture.
The 10V ~ 30V supply range sets the rail boundaries. A machine supply outside them rules the part out, while one inside them says nothing about output loading. The listed 400Hz response frequency is a ceiling for event-rate screening, not proof that every passing target will register at that rate. The operating temperature range runs from -40°C to 85°C; a location outside it is not covered by the stated rating.
Can the line accept an M18 body with cable leads?
Can the existing fixture take a threaded M18 cylinder with cable leads? On a running line, a connectorized harness cannot mate directly with the stated termination. Keep E2E-X16MC1L18 2M on the BOM only if the assembly can accommodate the cable-lead connection, and specify that connection before releasing the build.
The wiring and mounting details remain open
The wiring isn't settled. No pinout is given, so NPN-NO, 3-wire does not identify the leads for installation. The mounting drawing is also absent. An M18 thread and 16mm listed reach do not establish the clearance an unshielded sensor needs around metal, and the drawing is needed before fixture release.
The output load-current rating and target-dependent sensing curve are absent too. Without the former, input loading remains unresolved; without the latter, so does trip-point tolerance. Get both before fixture release.
View the Win-Source product page for E2E-X16MC1L18 2M.
Key Takeaways for Engineers & Buyers
- Check the 16mm sensing distance against the actual target and mounting clearance.
- Match the NPN-NO, 3-wire output to the receiving input.
- Keep the supply within the listed 10V ~ 30V range.