16mm sensing distance, M18 threaded body, 10V ~ 30V supply limits, -40°C ~ 85°C operating span.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
16mm reach makes target testing the first decision
16mm is the listed sensing distance. It doesn't promise switching for every metal target at that point. Test the intended target in its mounting position before committing Omron E2E-X16MC1L18 5M to a new design. The part is listed Active, with no conflict among its lifecycle signals and no stated lifecycle reason to restrict it to sustaining designs. It is also listed EU RoHS compliant.
The unshielded M18 body is not a flush-mount assumption
A flush-mounted installation without a clearance check is the wrong fit. The M18 threaded cylinder is unshielded, and the thread says nothing about permissible surrounding metal. For inductive target detection, work out the mounting clearance before choosing the position. The listed 400Hz response frequency is a starting point for event-rate screening; it does not establish switching delay for the actual target. A missed detection is a poor way to discover the difference.
Supply limits and cable leads set the integration work
The 10V ~ 30V supply range forces a rail check at both ends. Treat 30V as the upper listed limit, not a working setpoint, and check the lower 10V bound at the sensor. The -40°C ~ 85°C operating-temperature span supports ambient screening, but 85°C is a ceiling, not permission to ignore heat at the mounting point. Neither range settles the electrical connection.
With an NPN-NO, 3-Wire output, the receiving input must be wired for that output rather than merely assigned a spare channel, and the cable-lead termination belongs in the build instructions before operators have to decide it at the station. The listed Box packaging does not change that installation task.
The M18 thread helps; the missing drawing still matters
The missing mounting drawing is the weak point. The listed M18 thread identifies the housing interface, but the datasheet must still supply the mounting drawing, lead pinout and output-current limit before the bracket and input circuit can be released.
View the Win-Source product page for E2E-X16MC1L18 5M.
Key Takeaways for Engineers & Buyers
- Test the intended target at the listed 16mm sensing distance.
- Match the 10V ~ 30V supply range and NPN-NO output to the input circuit.
- Specify cable-lead termination for the M18 installation.