16mm sensing distance, 10V–30V supply bounds and an M18 threaded body set the first fit checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in, but cable leads shape assembly
That leaves the design-in case intact: Omron E2E-X16MC218 2M is marked Active in both lifecycle and product-status fields, with no conflicting signal between them. EU RoHS compliance is listed. Cable leads complicate assembly; specify termination and strain relief before fixing the sensor's position in the M18 mount.
The supply bounds do not settle transient tolerance
The limits are clear. The supply range has a 10V lower bound and a 30V ceiling; those bounds don't establish tolerance to rail transients. The -40°C to 85°C operating range screens the installation environment, not output loading.
An unshielded M18 sensor needs a target trial
It won't suit a controller input that cannot accept NPN-NC, 3-wire signaling, or a mounting plan that assumes a shielded sensing face. E2E-X16MC218 2M is unshielded, with a threaded M18 body that needs a matching mount and room for its cable leads.
The listed 16mm sensing distance is a reach limit, not a guarantee that every metal target switches there. Trial the actual target in its installed position before fixing the trigger point. The 400Hz response frequency can screen a moving-target application, but it is not a response-time specification; a missed target can still mean a missed count.
M18 is specified; the mounting drawing is not
The mounting drawing is missing, although the M18 thread establishes the mounting format. Obtain the drawing and cable wiring assignment before releasing bracket and termination instructions. Sensing-distance test conditions and an output load-current limit are also absent, so the target trial and controller load check remain open.
View the Win-Source product page for E2E-X16MC218 2M.
Key Takeaways for Engineers & Buyers
- Check rail excursions against the 30V supply ceiling.
- Trial the 16mm sensing limit with the actual target and M18 mount.
- Specify cable-lead termination in the production assembly plan.