16mm sensing distance, 10V ~ 30V supply limits, M18 thread, and NPN-NC output set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status leaves sensing fit to decide
It remains a new-design candidate. Omron E2E-X16MC218-R 5M has Active lifecycle and product statuses with no stated conflict, so lifecycle status does not confine it to sustaining designs. It is marked EU RoHS compliant.
The decision rests at the machine. The inductive sensor must see the intended target, and its NPN-NC, 3-wire output must match the controller input. If that input expects the opposite contact behavior, Active status will not fix the controls scheme.
The M18 body will not solve a shielded mounting requirement
A shielded installation rules this sensor out. It is unshielded, with an M18 threaded body and cable leads; the bracket and cable route must suit that construction. The M18 thread won't change the mounting requirement.
The stated 16mm sensing distance does not establish that every target switches at that spacing. The 10V lower supply bound and 30V upper ceiling define the rail limits, not a permissible output load. Its -40°C ~ 85°C operating-temperature range bounds the installed environment; outside that range, the stated sensing distance is no basis for sign-off.
Order the cable-lead version by its full suffix
And that construction needs to survive ordering. Box is the stated package; cable leads are the termination. Neither is captured by a generic “M18 NPN-NC sensor” description. Specify the full E2E-X16MC218-R 5M order code.
What does 400Hz leave unresolved?
Response time isn't specified. The stated 400Hz response frequency frames an event-rate test, but without a response-time specification it cannot establish whether a moving target produces an input transition when the controller needs it.
The mounting drawing is also absent. M18 names the thread, not the space required around the body or cable exit. Without a wiring diagram, the conductor assignments remain unresolved; without an output-current limit, the controller input load cannot be checked from these figures. Those gaps, rather than Active status, determine whether the bracket and input circuit can be released without rework.
View the Win-Source product page for E2E-X16MC218-R 5M.
Key Takeaways for Engineers & Buyers
- Keep the control rail within the 10V ~ 30V supply limits.
- Check the 16mm sensing distance against the actual target.
- Keep the full E2E-X16MC218-R 5M suffix on the purchase line.