16mm sensing distance, 10V to 30V supply and an M18 threaded body with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR INDUCT 16MM NPN M18 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
Active status supports a new M18 sensor design-in
And that leaves new design-in on the table. Omron E2E-X16MC2L18 2M is Active across the lifecycle fields, with no conflict, and is EU RoHS compliant. The listed 16mm sensing distance makes it worth considering for an M18 machine mount, but does not establish the switch point for every target. An input wired for the opposite switching behavior rules out its NPN-NC, 3-wire output before mounting begins.
The supply and response limits set different boundaries
The limits are clear. The 10V to 30V supply range bounds rail choice: 30V is its upper listed limit rather than a nominal setpoint, while 10V is its lower limit rather than evidence that supply dips are harmless. The 400Hz response-frequency ceiling rules out assuming the sensor can count faster events, but it doesn't specify switching delay at a particular target. Operating temperature spans -40°C to 85°C; the 85°C upper limit does not establish thermal margin beside hot tooling. IP67 and IP69K describe ingress protection, not how to route the cable.
Cable leads put work on the assembly plan
Cable termination constrains assembly. The part comes in a box, and its leads need a defined termination and routing operation at the M18 mount. Put that operation on the build plan before releasing the new-design BOM.
The 16mm distance cannot settle target or mounting details
The sensing curve is missing, but the listed 16mm distance gives a starting point for a fixture check. Get the target-dependent curve for the actual target before fixing standoff. The mounting drawing is absent, so clearance around the unshielded M18 body remains open. The missing cable pinout leaves the NPN-NC lead connections open too. Switching-delay detail is absent as well, so the 400Hz ceiling can't serve as an edge-timing specification.
View the Win-Source product page for E2E-X16MC2L18 2M.
Key Takeaways for Engineers & Buyers
- Match the control rail to the 10V to 30V supply limits.
- Check that the input accepts NPN-NC, 3-wire signaling.
- Plan cable-lead routing at the M18 mount.