16mm sensing, 12V–24V supply, M18 threaded body; RoHS entries conflict.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 16MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NO, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 12V ~ 24V |
Active status does not settle the RoHS conflict
An EU RoHS-controlled build is a poor place to commit this sensor today. Active status supports new design-in on lifecycle grounds, but E2E-X16MD1L-T 2M has a RoHS Compliant field and a RoHS Non-Compliant specification. Resolve the conflict with Omron before BOM approval.
The supply range and response frequency set separate boundaries
The 12V–24V supply range limits the sensor rail. Its lower boundary is 12V, and 24V is a ceiling, not extra headroom. The range does not establish what voltage a connected input sees when the output switches.
Event speed is a separate constraint. The 400Hz response-frequency listing can rule out jobs needing faster detection, but it doesn't establish reliable detection of a particular moving target without the timing conditions for that target. Placement is bounded by the -25°C to 70°C operating range: 70°C is an upper limit, not a target for a hot enclosure. Treating these boundaries as spare margin risks missed counts or operation outside the listed range.
A 16mm sensing distance still needs a mounting decision
16mm is the listed sensing distance, not a promise that every target at that gap will switch. At a metal-target detection point, check that distance against the actual target and surrounding metal. The inductive sensor has an unshielded, threaded M18 body, and its cable leads make routing part of the installation. IP67 is the listed ingress rating, not a verdict on the installed cable route or mounting arrangement.
For an existing line, bulk packaging calls for explicit cable-lead handling instructions.
The missing output and mounting details can still stop release
Release is premature. Without off-state leakage and on-state residual voltage, the normally open, 2-wire output cannot yet be checked against the receiving input. The target-dependent sensing-distance curve and mounting drawing are also absent. Get those details before fixing the detection gap, surrounding-metal clearance, bracket or input circuit.
View the Win-Source product page for E2E-X16MD1L-T 2M.
Key Takeaways for Engineers & Buyers
- Keep the sensor rail within 12V–24V; treat 24V as the upper boundary.
- Check M18 mounting clearance for the unshielded body.
- Resolve the conflicting EU RoHS entries before BOM approval.