0.709" (18mm) sensing distance, M30 body, 10V ~ 30V supply, and PNP-NO output set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 18MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Active status leaves the unshielded mount to prove
Even so, the Active lifecycle fields agree for E2E-X18MB1D30 2M, with no conflicting status. EU RoHS compliance is listed. Neither establishes whether the unshielded sensing face will work in the intended mount.
Will the M30 bracket and PNP input work together?
Will it fit the M30 bracket and work with the controller input? The M30 threaded cylinder fixes the bracket family, while the unshielded construction puts surrounding metal into the sensing check. The listed 0.709" (18mm) sensing distance is the reach to evaluate against the actual target before fixing the bracket; it doesn't guarantee detection at the edge of that distance.
The PNP-NO, 3-Wire output needs an input that accepts a sourcing, normally open signal, or the controller may miss a detected target. The 10V ~ 30V supply range sets the bounds for the rail, not a preferred setpoint. Cable leads bring termination and routing into the installation plan rather than leaving a connector choice for assembly.
100Hz puts fast targets on the test bench
Fast targets need a bench test. The listed 100Hz response frequency is a switching-rate ceiling to compare with target events; events beyond it risk missed detections. The -40°C ~ 85°C operating temperature range bounds the sensor-temperature check. IP67 and IP69K ingress ratings support considering wet placements, but they don't settle cable routing or exposure.
The missing output limit holds up wiring release
The output load-current limit is missing, so the electrical-interface check cannot close here, even though the M30 thread and PNP-NO output narrow the hardware choice. Bracket release still needs a mechanical drawing, and wiring needs a pinout. Sensing-distance test conditions are also absent; they matter when the actual target differs from the test target.
View the Win-Source product page for E2E-X18MB1D30 2M.
Key Takeaways for Engineers & Buyers
- Check the 0.709" (18mm) sensing distance against the target and unshielded mount.
- Match the PNP-NO, 3-Wire output to the controller input before wiring the cable leads.
- Compare the required event rate with the listed 100Hz response frequency.