18mm sensing distance, 10V ~ 30V supply limits, M30 threaded body; PNP-NO output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 18MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Is this M30 sensor a new-build choice?
Can I specify this sensor for a new machine build? Yes. E2E-X18MB1D30 5M is marked Active, with no conflicting lifecycle signal; its PNP-NO, 3-Wire output identifies the switching type, and EU RoHS compliance is listed.
For an existing line, don't assume a plug-in connection: specify cable-lead termination on the BOM. The Box designation describes packaging, not the machine connection.
The 18mm reach does not settle the switching layout
18mm is the listed sensing distance, but target and mounting conditions are needed before setting clearance; the 10V ~ 30V supply limits bound the rail choice, not the controller connection.
The 100Hz response-frequency rating is a ceiling for repeated detection, not a guaranteed minimum pulse width at the input. The -40°C ~ 85°C operating-temperature range excludes locations outside those limits.
An unshielded M30 body changes the bracket
Bracket geometry is the constraint for this unshielded, threaded M30 cylinder: nearby metal matters to the sensing position, and the mount must not assume flush installation. IP67 and IP69K address ingress protection, not sealing at the cable end.
What still blocks the hookup and target clearance?
The output load-current limit is missing, even though the switching interface is identified as PNP-NO, 3-Wire. Obtain the wiring diagram before connecting the cable leads to a controller input; target-dependent sensing conditions and an unshielded mounting drawing are still needed before fixing the bracket. Neither the ingress ratings nor the identified switching type resolves the electrical hookup or target clearance.
View the Win-Source product page for E2E-X18MB1D30 5M.
Key Takeaways for Engineers & Buyers
- Set target clearance against the listed 18mm sensing distance; obtain the target conditions.
- Keep the controller supply within the 10V ~ 30V limits.
- Match the input to PNP-NO, 3-Wire switching; obtain the output load-current limit.