18mm sensing distance, 100Hz response ceiling, M30 body and cable leads
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 18MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
The 18mm reach depends on how the unshielded M30 body mounts
18mm is the listed sensing-distance ceiling. With an unshielded, threaded M30 body, E2E-X18MB1DL30 2M needs a bracket position that accounts for metal around the sensing face, since a nominally reachable target can otherwise be missed. That reach isn't a promise for every target or mounting arrangement.
The PNP-NO, 3-wire output needs a matching controller input; replacing a sensor with a different output type still leaves the wiring open.
The 100Hz ceiling screens event rate, not detection time
100Hz is the listed response-frequency ceiling, not a detection-time guarantee for a short target at line speed. The -40°C to 85°C operating-temperature range brackets the installation environment, but the mounting-point temperature remains open.
Active status supports design-in; the connection is still open
Design it in. E2E-X18MB1DL30 2M has aligned Active lifecycle signals and no listed lifecycle reason to limit it to sustaining designs; it is also marked compliant with EU RoHS. The 10V to 30V supply bounds screen the controller rail, not the sensor’s tolerance of disturbances on that rail.
The datasheet still needs to supply a wiring diagram to settle cable-lead assignments and a mechanical drawing to settle bracket dimensions. An output-current limit is also needed to establish the permitted input load. Those details aren't recoverable from the sensing-distance figure. Hold wiring and bracket release until they are in hand.
Can the line accommodate cable leads instead of a connector?
Does the installed harness expect a connector at the sensor? E2E-X18MB1DL30 2M has cable leads instead, so it is not a direct wiring match. Box is its listed package. Put the cable termination and threaded mounting arrangement on the build instructions before committing the sensor to an existing production line.
View the Win-Source product page for E2E-X18MB1DL30 2M.
Key Takeaways for Engineers & Buyers
- Check target spacing against the listed 18mm sensing-distance ceiling.
- Screen event rate against the 100Hz response-frequency ceiling.
- Map the 3-wire PNP-NO output to the controller input.