Omron E2E-X18MB1TL30 2M: Active for New Machine Designs

E2E-X18MB1TL30 2M Omron product image

18mm sensing distance, 100Hz response frequency, M30 body, and PNP-NO cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 18MM PNP M30 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

An unshielded M30 head changes the mounting decision

Don't use this sensor with an NPN input or where a shielded head is required. In a threaded M30 body with cable leads, E2E-X18MB1TL30 2M is an unshielded inductive PNP-NO, 3-wire device for a machine bracket facing a metal target, with room to route the leads.

The listed 100Hz response frequency is a screening figure for moving targets, not a stated switching delay or proof that a brief event will be detected. IP67 and IP69K are the stated ingress ratings; neither establishes tolerance to cleaning chemicals. These distinctions matter when a missed target stops a machine or a mounting change reaches an existing line.

Active status supports a new machine BOM

Can we design this into a new machine? Yes. Omron lists E2E-X18MB1TL30 2M as Active, with no conflict among the lifecycle signals. That supports new design-in and continued use in existing production. EU RoHS compliance is also stated.

The build constraint is its cable-lead termination, not a plug. Put lead routing and termination into the assembly instructions before a running line reaches installation expecting a mating connector. The package entry is Box.

The 18mm distance sets the target path, not every target result

18mm is the listed sensing distance. Use it to evaluate target placement, not to assume a response to every metal target shape. The 10V to 30V supply range bounds rail selection; 30V is the listed ceiling, not a setpoint to exceed.

The operating-temperature range tops out at 85°C. This listing does not support a hotter sensor location, even if the machine's ambient temperature is lower.

The mount and input still need sensor-specific details

The listing isn't enough. It lacks a cable-lead pinout, an M30 dimensional drawing, and a target-dependent sensing curve. Those gaps leave the wiring and bracket clearance unresolved, along with whether the 18mm figure works for the actual target.

View the Win-Source product page for E2E-X18MB1TL30 2M.

Key Takeaways for Engineers & Buyers

  • Allow M30 bracket clearance around the unshielded head.
  • Match the PNP-NO, 3-wire output to the machine input.
  • Screen moving-target events against the listed 100Hz response frequency.