18mm sensing, 10V ~ 30V supply, M30 thread: target clearance and output load remain open.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 18MM PNP M30 NO |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Can this Omron sensor go into a new machine build?
Is this sensor active for a new machine build? Yes. E2E-X18MB1TL30-M1 is marked Active in both lifecycle and product status, with no conflicting signal. EU RoHS compliance is listed. On an existing production line, keep the M30 mounting and connector termination on the controlled BOM; an electrical match cannot rescue a changeover if the sensor will not fit.
The supply range does not settle the PNP output load
The 10V ~ 30V supply range draws a hard line: a rail outside it rules out the sensor. It isn't a load rating. The PNP-NO, 3-wire output must suit the input logic before panel wiring is committed, and the output load-current limit is needed to assign the connected load. The listed 100Hz response frequency provides an event-rate check, not a switching waveform or proof that every narrow event will be captured.
An 18mm target distance needs room around the M30 face
18mm is the listed sensing distance, not a promise of that reach for every target or mounting arrangement. The unshielded inductive head needs room around its sensing face on the M30 threaded cylinder; neither a flush recess nor a nonmetal target is established as a fit here. Mounting can stop a retrofit before the supply range matters. The nickel-plated brass body and connector termination describe the installation, but do not identify the mating connector.
Ingress ratings are clear; installation details are not
The weak point is the unfinished installation detail, not the environmental ratings. IP67 and IP69K ingress ratings, alongside the -40°C ~ 85°C operating-temperature range, make a washed machine location plausible, but do not establish whether the connector interface retains those ratings after installation. The connector pinout and mechanical drawing are absent, leaving cable assignment and clearance around the unshielded face open.
Get the pinout and drawing before fixing the bracket and panel wiring. The output load-current limit is also absent: PNP-NO identifies output behavior, not how much load the output can carry. A target-material sensing curve is missing too, so the listed 18mm distance cannot settle detection of the actual metal in front of the head. Those gaps determine whether the installation detects reliably and whether the connected load exceeds the output's limit. The LED indicator settles neither question.
View the Win-Source product page for E2E-X18MB1TL30-M1.
Key Takeaways for Engineers & Buyers
- Match the 10V ~ 30V supply range to the machine rail.
- Check the M30 mounting drawing for clearance around the unshielded face.
- Get the output load-current limit before assigning the PNP-NO output.