Omron E2E-X18MB3DL30-M1: Active for New Designs

E2E-X18MB3DL30-M1 Omron product image

18mm sensing distance, M30 thread, 10V ~ 30V supply limits, -40°C ~ 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 18MM PNP M30 NO/NC
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Active status leaves the M30 fit to decide

Design it in. Omron E2E-X18MB3DL30-M1 is marked Active across the lifecycle fields, with no conflicting status forcing a sustaining-only choice. EU RoHS is marked compliant. Fit of the unshielded, connector-ended sensor remains the release decision.

Will this connector-ended M30 unit fit the running line?

Will the M30 connector version fit the running line? The boxed unit is a connector-terminated, threaded M30 cylinder; its mechanical and wiring interfaces determine the fit. Keep E2E-X18MB3DL30-M1 on the existing production BOM and match its connector to the installed cable before ordering; the specified PNP-NC/NO, 3-wire output doesn't establish pin assignment or how the output choice is wired.

An 18mm reach does not settle target placement

And the sensing face isn't a free pass on placement. The listed 18mm sensing distance gives a starting point for a metal-target station, but this is an unshielded inductive sensor: nearby metal and the actual target still matter to the installed gap. Its listed 100Hz response frequency does not establish detection of every brief passing target. IP67 and IP69K support the enclosure choice for a wet area, but neither rating establishes how the connector seals once installed.

The 30V ceiling leaves wiring and mounting questions open

30V is the listed supply ceiling, not a rail target; 10V is the lower listed boundary, so a supply outside those limits rules out this part as specified. The -40°C ~ 85°C operating-temperature range brackets the stated environment, but it does not establish the permissible output load at temperature.

Get the connector pinout, an unshielded mounting-clearance drawing, and the output load-current limit from the datasheet. None is listed here. Without those items, a sensor that threads into the station could still switch incorrectly beside metal or drive a load beyond its output limit.

View the Win-Source product page for E2E-X18MB3DL30-M1.

Key Takeaways for Engineers & Buyers

  • Set target placement against the listed 18mm sensing distance.
  • Keep the 10V ~ 30V supply limits in the electrical check.
  • Match the connector and pinout before ordering E2E-X18MB3DL30-M1.