Omron E2E-X18MC130-M1: Active, With a Distance Conflict

E2E-X18MC130-M1 Omron product image

18mm listed sensing distance, 10V to 30V supply, M30 body—and a conflicting 15MM description.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR INDUCT 15MM NPN M30 NO
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

An NPN input is the starting point

A PNP-only input rules this sensor out. E2E-X18MC130-M1 is an inductive, NPN-NO, 3-wire device with a connector termination; it needs an input built for that switching polarity.

Omron marks it Active across its lifecycle fields. New design-in is reasonable once the sensing-distance conflict is settled, and existing production has no stated lifecycle conflict to resolve. It is listed as EU RoHS compliant.

The supply range does not settle switching speed

10V to 30V is the listed supply range, not permission to run above 30V or below 10V. The operating temperature range is -40°C to 85°C; a location outside it needs a different sensor or a changed installation.

The listed 100Hz response frequency matters when targets pass quickly, but it does not establish that every target geometry will produce a clean input transition at that rate. Compare the event-rate requirement with 100Hz rather than relying on the LED as proof that the installation is working.

An 18mm entry and a 15MM description cannot both guide tooling

18mm is the listed sensing distance. The product description says 15MM. That disagreement could leave a target outside the detection position built into a fixture, so resolve it before fixing the sensor-to-target gap. Neither figure alone establishes detection for a particular target material and shape.

The unshielded M30 threaded body sets the mounting approach, while the connector termination makes identifying the mating connection an immediate task before a machine build is released. The Box packaging field does not answer that connection question.

The missing details still decide the M30 installation

And the headline specifications can't close the wiring and target-gap decisions without the connector pinout, output load-current limit and sensing-distance conditions. None is listed here; those details still have to come from the datasheet.

View the Win-Source product page for E2E-X18MC130-M1.

Key Takeaways for Engineers & Buyers

  • Resolve the 18mm sensing entry against the 15MM description before fixture tooling.
  • Match the NPN-NO, 3-wire output to the receiving input.
  • Check the 100Hz response frequency against the target event rate.