18mm listed reach conflicts with 15MM description; M30 body, 10V ~ 30V supply
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR INDUCT 15MM NPN M30 NC |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Is the sensing reach settled enough to specify?
Can this go into a new machine build? Both lifecycle and product status are Active for E2E-X18MC230-R 2M, and it is listed as EU RoHS compliant. But the sensing-distance field says 18mm while the product description says 15MM. Those entries can't both set target clearance. Resolve the discrepancy before fixing that mechanical dimension.
An M30 inductive sensor, not a PNP input match
A PNP control input is the wrong match. E2E-X18MC230-R 2M has an NPN-NC, 3-Wire output and belongs in an inductive detection position with room for its unshielded M30 threaded body and cable leads. The 18mm sensing-distance entry is a starting point for target placement, not a settled clearance while the 15MM description disagrees with it.
The 10V ~ 30V supply entry sets the listed electrical range, with 30V as its ceiling rather than evidence that the sensor tolerates a supply above that limit. The -40°C ~ 85°C operating-temperature range puts 85°C at the listed ceiling; a hotter mounting location falls outside it. The 100Hz response-frequency entry limits event-rate selection but gives no switching delays for judging a brief target pass.
Cable leads decide the assembly step
Cable leads govern assembly. The Box package entry doesn't change the connection: the line needs a cable termination process, not an assumed integral connector. Include that step with the M30 mounting requirement in the build instructions. With both lifecycle signals Active, this is a new-design candidate rather than a sustaining-only purchase once the reach conflict is closed.
The 30V ceiling does not size the NPN load
The 30V supply ceiling leaves the NPN input load unchecked because the output-current limit is absent. The pinout and mounting drawing are also absent, leaving cable wiring and final mounting geometry open.
View the Win-Source product page for E2E-X18MC230-R 2M.
Key Takeaways for Engineers & Buyers
- Resolve the 18mm sensing entry against the 15MM description before setting target clearance.
- Match the 10V ~ 30V supply range and NPN-NC, 3-Wire output to the control input.
- Plan the M30 mounting and cable-lead termination together.