18mm sensing distance, 10V ~ 40V supply range, M30 threaded case; discontinued.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 18MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 40V |
Can this sensor stay on a running line?
Can we keep this sensor on a running line? Yes, as a sustaining part, but not for a new machine. The lifecycle field says EOL; both status fields say Discontinued. The wording differs, but the design-in decision doesn't. Secure inventory for existing production and plan migration rather than putting E2E-X18ME2 on a new bill of materials. Bulk packaging does not change that constraint. It is EU RoHS compliant.
Does 100Hz cover the target rate?
100Hz is the listed response-frequency ceiling. It gives a limit for assessing passing targets, not a switching waveform or permission to assume every target geometry will register at that rate.
What do 18mm and M30 actually buy you?
18mm is the listed sensing distance, not the body diameter or a guaranteed trip point for every metal target. The description calls this an 18MM cylinder, while the case field specifies an M30 threaded body. Check the mounting envelope before treating those descriptions as interchangeable.
The 10V ~ 40V supply range sets the electrical boundary; 40V is a ceiling, not a preferred setpoint or a transient allowance. The -40°C ~ 85°C operating range bounds where the sensor may be specified, but does not settle how its cable leads will be routed. The unshielded inductive head belongs at a machine-mounted target position where the M30 body fits and nearby metal will not upset detection. The NPN-NC, 3-Wire output must also match the input circuit; it is not a drop-in choice for a different output arrangement.
What still prevents a mounting and wiring sign-off?
Even so, the case description cannot settle the fit by itself. The mechanical drawing is absent, leaving the M30 mounting envelope unresolved. The cable-lead wiring diagram and output load-current limit are also absent. Without them, the input connection and load cannot be signed off from these specifications.
View the Win-Source product page for E2E-X18ME2.
Key Takeaways for Engineers & Buyers
- Plan migration from E2E-X18ME2; its product status is Discontinued.
- Check target position against the listed 18mm sensing distance.
- Get the cable-lead wiring diagram before connecting the NPN-NC output.