20 VAC to 264 VAC supply limits, 18mm sensing distance, M30 threaded case, 25Hz response limit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 18MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
An AC inductive sensor, not a DC input swap
DC-powered sensing is the wrong job here. Listed Active, E2E-X18MY1 2M remains a new-design candidate where an inductive sensor with an SCR-NO, 2-Wire output matches the input circuit. Its 20 VAC and 264 VAC supply limits bound that choice; they do not specify allowable load current or voltage across the switched load. The 25Hz response rating is a ceiling for target events, not a promise that a faster count will register. EU RoHS compliance is listed.
Will the M30 mount carry over to the running line?
Can the running build keep this sensor? Active status supports that choice, but the M30 threaded case and cable-lead termination must match the build record. Box packaging changes neither interface.
The 18mm reach is not an 18mm housing drawing
And the mechanical label still needs sorting out: the description says “18MM CYL,” while the case field says M30 threaded and the sensing-distance field says 0.709″ (18mm). Don't cut a mounting hole from the description. The listed 18mm sensing distance does not establish clearance for every metal target or nearby metal installation, particularly with unshielded sensing. The -25°C to 70°C operating-temperature range and IP67 rating help screen the installation environment; neither resolves target clearance.
25Hz settles speed, not the input circuit
25Hz is the listed response-frequency ceiling. It can rule out a fast counting job, but it cannot qualify the sensor's behavior at the connected input. The missing wiring diagram and allowable load-current specification matter for the SCR-NO, 2-Wire connection. A mounting drawing must settle the M30-versus-“18MM CYL” ambiguity, and a target-dependent sensing-distance curve must establish usable clearance before the fixture and electrical interface are signed off.
View the Win-Source product page for E2E-X18MY1 2M.
Key Takeaways for Engineers & Buyers
- Check the AC supply against the 20 VAC to 264 VAC listed limits.
- Compare the required count rate with the 25Hz response ceiling.
- Resolve the M30 case and “18MM CYL” description against the mounting drawing.