18 mm sensing distance, 20 VAC to 264 VAC supply range and M30 threaded body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 18MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
Wrong for DC inputs; viable for AC presence detection
A DC input is the wrong destination. E2E-X18MY1-M1 belongs in an AC-fed industrial presence-detection circuit that accepts an SCR-NO, 2-wire output. Active lifecycle signals support new design-in where that interface fits. EU RoHS compliance is stated.
The 18 mm reach is not a mounting guarantee
18 mm is the listed sensing distance, not a promise that every target will switch at that separation. With an unshielded inductive head, target position and nearby metal need checking in the actual mount, because a missed target can leave a machine input silent. The M30 threaded body fixes the mounting interface, but the “18MM CYL” wording isn’t a mounting-hole dimension.
Supply is specified from 20 VAC to 264 VAC. Treat 264 VAC as a ceiling, not a preferred operating point. The listed 25 Hz response frequency limits the switching-rate case supported here; it does not establish how short a passing target can be and still register.
Bulk packaging changes how this M30 sensor reaches the line
That mounting choice carries into production. E2E-X18MY1-M1 comes in bulk with a connector termination; no individually protected format is stated. Protect the thread and connector before assembly: a bent thread can block installation even when the sensing circuit works. The stated -25°C to 70°C operating range sets the ambient-temperature fit. IP67 identifies the sensor’s ingress-protection rating, not a rating supplied here for an unspecified mating connector.
The missing output and mechanical details still matter
Installation detail is the weak point, despite the clear Active status. Without a mechanical drawing, the conflicting cylinder description and M30 mounting callout cannot be resolved here. Connector pinout, off-state leakage and load-current limits are also absent; without them, the intended input circuit cannot be cleared for a reliable off state or a permissible load.
View the Win-Source product page for E2E-X18MY1-M1.
Key Takeaways for Engineers & Buyers
- Check the 18 mm sensing distance against the actual target and mounting position.
- Match the SCR-NO, 2-wire output to the intended input circuit.
- Account for bulk packaging when staging E2E-X18MY1-M1 at the line.