Omron E2E-X18MY1-M1: Active for AC proximity sensing

E2E-X18MY1-M1 Omron product image

18 mm sensing distance, 20 VAC to 264 VAC supply range and M30 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 18MM CYL
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC

Wrong for DC inputs; viable for AC presence detection

A DC input is the wrong destination. E2E-X18MY1-M1 belongs in an AC-fed industrial presence-detection circuit that accepts an SCR-NO, 2-wire output. Active lifecycle signals support new design-in where that interface fits. EU RoHS compliance is stated.

The 18 mm reach is not a mounting guarantee

18 mm is the listed sensing distance, not a promise that every target will switch at that separation. With an unshielded inductive head, target position and nearby metal need checking in the actual mount, because a missed target can leave a machine input silent. The M30 threaded body fixes the mounting interface, but the “18MM CYL” wording isn’t a mounting-hole dimension.

Supply is specified from 20 VAC to 264 VAC. Treat 264 VAC as a ceiling, not a preferred operating point. The listed 25 Hz response frequency limits the switching-rate case supported here; it does not establish how short a passing target can be and still register.

Bulk packaging changes how this M30 sensor reaches the line

That mounting choice carries into production. E2E-X18MY1-M1 comes in bulk with a connector termination; no individually protected format is stated. Protect the thread and connector before assembly: a bent thread can block installation even when the sensing circuit works. The stated -25°C to 70°C operating range sets the ambient-temperature fit. IP67 identifies the sensor’s ingress-protection rating, not a rating supplied here for an unspecified mating connector.

The missing output and mechanical details still matter

Installation detail is the weak point, despite the clear Active status. Without a mechanical drawing, the conflicting cylinder description and M30 mounting callout cannot be resolved here. Connector pinout, off-state leakage and load-current limits are also absent; without them, the intended input circuit cannot be cleared for a reliable off state or a permissible load.

View the Win-Source product page for E2E-X18MY1-M1.

Key Takeaways for Engineers & Buyers

  • Check the 18 mm sensing distance against the actual target and mounting position.
  • Match the SCR-NO, 2-wire output to the intended input circuit.
  • Account for bulk packaging when staging E2E-X18MY1-M1 at the line.