1mm sensing, a 3kHz response ceiling and an M5 threaded body; discontinued status rules out new design-in.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M5 |
| Core function | SENSOR PROX INDUCTIVE 1MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V |
The discontinued M5 sensor belongs on existing lines
A new machine is the wrong place for E2E-X1B2. Its records disagree on EOL versus Discontinued, but neither supports new design-in. On an existing line that calls for a shielded inductive sensor in an M5 threaded body, the PNP-NC, 3-wire output and cable leads also have to match the installation. A different output behavior or mount changes more than the BOM.
Bulk packaging does not remove the lifecycle problem
Even then, bulk packaging doesn't solve the lifecycle problem. Secure inventory for existing production and plan migration. One RoHS record says compliant, the other non-compliant; hold compliance release until that conflict is resolved.
The 1mm reach makes target position decisive
The reach is tight. The listed 1mm sensing distance makes the installed target position the immediate check; it does not establish detection for every target material or shape. The listed 3kHz response frequency is a ceiling, not a switching waveform or a promise about every event on a fast line. A shielded M5 threaded body may fit the existing mount, but that alone says nothing about repeatable detection at the target.
The 30V ceiling cannot qualify the PNP-NC load
The 10V ~ 30V range bounds the controller rail. It does not establish how much current the PNP-NC, 3-wire output can deliver into an input, so the 30V ceiling cannot qualify the load on its own. Treat 30V as a ceiling, not a nominal setting; 10V is the lower listed boundary, not proof of behavior during a rail sag. The -25°C ~ 70°C operating-temperature range screens the installation: locations outside either endpoint fall outside the listed range. IP67 addresses ingress protection, but cable leads still need a suitable termination in the machine. The LED offers local indication, not a measure of switching time. The output-load question remains open.
The M5 mount still needs a drawing
3kHz cannot rate the output load. The listing lacks an output-current limit and switching hysteresis, along with a wiring diagram and dimension drawing. Those items are needed to settle input loading, repeatable detection and physical M5 fit before a sustaining-line change is released.
View the Win-Source product page for E2E-X1B2.
Key Takeaways for Engineers & Buyers
- Check the installed target against the listed 1mm sensing distance.
- Match the controller supply to the 10V ~ 30V listed limits.
- Resolve the conflicting RoHS statuses before release.