Omron E2E-X1C1-R: Discontinued, for sustaining use only

E2E-X1C1-R Omron product image

1mm sensing distance, 10V–30V supply limits, M5 thread, -25°C to 70°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M5
Core functionSENSOR PROX INDUCTIVE 1MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 3kHz; Voltage - Supply: 10V ~ 30V

Discontinued status rules out a new design-in

No new design-ins. E2E-X1C1-R is marked Discontinued in its lifecycle and product status fields; another lifecycle signal says EOL. For existing production, secure inventory and plan migration. The compliance field says RoHS compliant, but the specification says non-compliant.

Supply limits and response frequency leave different questions

10V to 30V are the listed supply limits, not recommended rail setpoints. A control rail outside that range rules this sensor out. The -25°C to 70°C operating range screens installation temperature, but it does not establish margin inside a particular enclosure.

The listed 3kHz response frequency helps screen detection speed.

The M5 body fits close targets, not every sensor input

This part is wrong for a PNP input or a target that cannot be held at the listed 1mm sensing distance. For a close-range inductive sensing position, the M5 threaded body and NPN-NO, 3-wire output suit a matching mount and input, provided the target stays within that sensing distance. The shielded body may help with placement near surrounding metal, but no installation geometry is listed to settle clearance.

IP67 states the ingress protection; it does not settle how the cable leads will be protected in the installed assembly. E2E-X1C1-R comes in bulk packaging, so check lead identification against the existing harness before releasing parts to a running line. A wiring mismatch stops assembly even if the body fits the mounting point.

The 3kHz figure does not close the timing check

Timing remains unresolved at 3kHz. The response figure doesn't give the transition timing needed to judge a controller’s input timing. A dimensioned drawing is absent, so the M5 thread alone cannot settle installed fit. The listing also lacks a cable-lead pinout and an output load-current limit; those gaps leave wiring and input-load checks open.

View the Win-Source product page for E2E-X1C1-R.

Key Takeaways for Engineers & Buyers

  • Check the 1mm sensing distance against the installed target gap.
  • Keep the control rail within the listed 10V–30V supply limits.
  • Resolve the conflicting RoHS entries before releasing sustaining builds.