Omron E2E-X1R5B1D8-M1: Active for new machine builds

E2E-X1R5B1D8-M1 Omron product image

1.5mm sensing, 10V ~ 30V supply, threaded M8 body; output load and mating details remain open.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

1.5mm reach makes target gap the first test

1.5mm is the listed sensing distance for E2E-X1R5B1D8-M1. That makes target placement the first test: the figure leaves detection margin after bracket tolerances and target movement unresolved. The threaded M8, shielded inductive body suits a compact mount where a metal feature passes close to the sensor, but not a mechanism that cannot hold the gap.

The listed 2kHz response frequency is a ceiling for detection-rate screening, not a switching-delay specification. It can rule out an event rate above that ceiling; it can't settle timing at the controller input.

10V ~ 30V supply sets the rail boundaries

10V ~ 30V is the listed supply range. The lower boundary is 10V; 30V is the upper ceiling. A rail outside that range rules out the sensor. Inside it, the allowable output load remains unresolved, and the PNP-NO, 3-Wire output still has to match the controller input.

Active status supports this M8 sensor's design-in

New design-in is reasonable. E2E-X1R5B1D8-M1 has aligned Active lifecycle signals and listed EU RoHS compliance. The listed -40°C ~ 85°C operating temperature range bounds machine-environment screening, but it does not establish performance at every mounting position or connected load. Those limits matter alongside fit: an acceptable temperature range does not resolve the connector interface.

The connector-terminated, threaded M8 construction is a buying decision as well as a mounting detail. Resolve the mating interface before releasing the harness. A sensor that fits the bracket but not the installed connector stops the line. Its stainless-steel body and listed IP67 and IP69K protection support consideration in exposed machinery, though those ratings do not establish the protection of an unspecified mated connector.

PNP-NO output still needs a load limit

The pinout is absent, but the stated PNP-NO, 3-Wire output identifies the controller input to plan. The output load-current limit is also absent, so an input match does not establish whether the sensor can drive the installed load. The mechanical drawing and connector mating detail are missing too; get them before fixing the bracket and harness.

View the Win-Source product page for E2E-X1R5B1D8-M1.

Key Takeaways for Engineers & Buyers

  • Set the target gap against the listed 1.5mm sensing distance.
  • Match the 10V ~ 30V supply range to the control rail.
  • Get the connector pinout before releasing the M8 harness.