1.5mm sensing distance, 10V ~ 30V supply and threaded M8 body set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
Active, but wrong for a long target gap
Long-standoff detection is the wrong job for E2E-X1R5B1D8-M5. Its listed 1.5mm sensing distance puts the metal target close to the face; a fixture that cannot hold that gap gains nothing from the part’s Active status. For close-range presence detection, the shielded inductive sensor and threaded M8 body make it a reasonable new design-in candidate.
Omron’s lifecycle signals agree, with no stated conflict, and the part is marked EU RoHS compliant. That settles the lifecycle question, not the installed geometry.
The 2kHz rating cannot rescue a missed target
And a reachable target can still be missed. The listed 2kHz response frequency is a screening ceiling for event rate, not a guaranteed detectable pulse width in the installed fixture. Brief target passages can produce intermittent missed counts despite a clean bench test.
The PNP-NO, 3-wire output needs a compatible sourcing-sensor input; a controller setting alone will not make an input wired for the opposite output behavior compatible. The stainless-steel body and listed IP67 and IP69K ingress protection support use in wet or dirty machinery, but those ratings do not specify protection for the completed mating connection.
10V ~ 30V bounds the supply, not its excursions
30V is the listed supply ceiling. The installed supply must also meet the 10V lower bound at the sensor; neither limit settles what happens during voltage excursions at the connector. The stated -40°C ~ 85°C operating-temperature range screens the installation environment, not performance outside that range.
The connector termination creates a purchasing constraint. Specify a mating harness for the threaded M8 installation before releasing the assembly, or the sensor can arrive in its stated Box package while the line still lacks a usable connection.
The M8 connection still needs a drawing
The connector pinout is absent, though the PNP-NO, 3-wire output is specified. An M8 thread doesn’t establish sensor-face position or mating clearance without a mechanical drawing, which is also absent. Get both before freezing the bracket and harness. Without a response-time waveform, the 2kHz rating cannot settle target-pulse timing.
View the Win-Source product page for E2E-X1R5B1D8-M5.
Key Takeaways for Engineers & Buyers
- Check installed target travel against the listed 1.5mm sensing distance.
- Screen event frequency against the listed 2kHz response frequency.
- Obtain the connector pinout before fixing the PNP-NO, 3-wire harness.