1.5mm sensing distance, 10V ~ 30V supply, M8 body and -40°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
The short reach is the first gate for new machinery
The 1.5mm reach sets the mounting constraint. Omron marks this sensor Active across its lifecycle fields, so new design-in is reasonable and sustaining designs face no lifecycle-driven migration. It is EU RoHS compliant. That verdict still depends on a layout that holds the target within the listed reach; Active status doesn't rescue a mounting position that puts it farther away.
The supply range does not settle switching speed
2kHz is the listed response-frequency ceiling, not a guaranteed detection rate with every target. The 10V ~ 30V supply limits don't cover rail excursions outside that range. The -40°C ~ 85°C operating range screens ambient temperature, not detection reliability.
The M8 body suits a close target, not a long throw
Long-throw applications and inputs expecting a sinking switch are wrong for this part. The PNP-NO, 3-Wire output calls for an input wired to accept a sourcing sensor.
The shielded M8 threaded stainless-steel cylinder suits a compact metal bracket that holds the target close, but the listed 1.5mm sensing distance leaves little room for movement away from the sensing face. Cable leads fit a wired machine harness rather than a connector-based swap. IP67 and IP69K are listed ingress ratings, useful when screening an exposed installation, but neither establishes how the installed cable termination will be sealed. A poor termination can still become a field fault.
Will cable leads fit the existing build?
Will cable leads fit the line's wiring method? The listed termination is cable leads, and the package is a box—not a connectorized sensor ready to plug into an existing harness. Match the termination to the harness work instruction before releasing a new build or continuing an existing one. Keep E2E-X1R5B1T8 2M on the BOM where that connection is a deliberate choice; its Active status does not settle the wiring work.
What is missing before the bracket and input are released?
Not a wiring blueprint. The datasheet still needs to supply the cable-lead wiring assignment and body drawing. It also needs the output load-current limit and sensing correction for the intended target material. Without the load-current limit, the controller input cannot be cleared; without the drawing, the threaded body cannot be placed confidently in an existing bracket.
View the Win-Source product page for E2E-X1R5B1T8 2M.
Key Takeaways for Engineers & Buyers
- Check target travel against the listed 1.5mm sensing distance.
- Keep the supply rail within the listed 10V ~ 30V limits.
- Match the PNP-NO, 3-Wire output to the controller input.