Omron E2E-X1R5B1T8 5M: Active for New Machine Designs

E2E-X1R5B1T8 5M Omron product image

1.5mm sensing ceiling, 10V–30V supply bounds, M8 threaded body and cable leads.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

An Active M8 sensor, if the input matches

30V is the supply ceiling, not a rail setting. Omron E2E-X1R5B1T8 5M is suitable for new design-in when the supply stays within its listed 10V to 30V bounds and the controller input accepts a PNP-NO, 3-wire output. Moving the sensor won't fix an output mismatch.

Its lifecycle signals agree on Active, with no conflict restricting it to sustaining designs. It is marked compliant with EU RoHS. Those points support a new-machine choice, but they leave the physical fit open: a moving target can leave this short-reach inductive sensor's range even when the electrical interface is correct.

The 1.5mm reach sets the mounting decision

1.5mm is the sensing-distance ceiling. The target gap must be set at the fixture; target motion beyond that reach risks missed detections. The 2kHz response-frequency rating is also a ceiling, not proof that every target event will be captured.

The -40°C to 85°C operating-temperature range helps screen the installation environment. It doesn't extend the sensing distance or establish how the sensor behaves at the edges of that range.

Where the shielded M8 body belongs

This part is wrong for nonmetal targets or an installation that requires a connector at the sensor. It belongs close to a metal target, where the shielded, threaded M8 cylinder can be mounted and its cable leads routed to the machine wiring.

The stainless-steel body and listed IP67 and IP69K ingress protection make it worth considering in exposed machine locations. Neither rating tells you whether the target gap remains inside 1.5mm after the bracket and target are installed.

The missing details behind the M8 thread

Wiring detail is the weak point, though the output is identified as PNP-NO, 3-wire. Lead identification and the output-load limit are absent, so the controller connection cannot be settled here. A mechanical drawing and sensing-distance curve are also absent. The thread designation alone cannot establish mounting clearances or detection across target travel.

Will cable leads fit the installed harness?

Will the machine harness accept cable leads? E2E-X1R5B1T8 5M has cable-lead termination. Match that connection to the machine wiring before releasing the BOM.

View the Win-Source product page for E2E-X1R5B1T8 5M.

Key Takeaways for Engineers & Buyers

  • Keep the target gap within the 1.5mm sensing-distance ceiling.
  • Hold the sensor supply within the listed 10V–30V bounds.
  • Match the M8 threaded body and cable leads to the mount and harness.