Omron E2E-X1R5B1T8-M5: Active for new machine designs

E2E-X1R5B1T8-M5 Omron product image

1.5mm sensing distance, 10V–30V supply range and threaded M8 body set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

The 1.5mm reach puts bracket placement first

1.5mm is the listed sensing distance, not a gap to assume for every target. On this shielded inductive sensor, bracket position and moving metal target belong in the same fit decision: if their separation cannot stay within that distance, the output may miss the target. No target-material correction is listed, so the stated distance alone cannot settle a change in target metal.

The threaded M8 body suits a compact machine mount, but leaves little room to compensate for a poorly placed target by moving the sensor back.

The supply range fits only the right controller interface

10V–30V is the listed supply range. It can accommodate a matching control rail, but says nothing about what the output can drive. The sensor has a PNP-NO, 3-wire output; the receiving input must suit that switching arrangement. A controller expecting a different output type is not a wiring tweak away from a fit.

The listed 2kHz response frequency is a first check against rapidly passing targets, not a guaranteed minimum pulse width. That distinction matters if the controller must catch brief events.

Active status supports a new E2E-X1R5B1T8-M5 design-in

New design-in is reasonable. The lifecycle signals all say Active, with no recorded conflict, and EU RoHS compliance is listed. Active status won't settle the electrical and mechanical details needed to release a machine build.

The -40°C to 85°C operating-temperature range sets the environmental bounds: a location outside it is ruled out, while one inside it still has to meet the mounting and connection requirements. IP67 and IP69K ingress-protection ratings are listed, useful when selecting a sensor for a wet industrial area. They do not establish the protection of an unspecified mating connection. The stainless-steel body and threaded M8 form call for a mounted sensor, not a loose cable installation.

Box packaging is the stated buying constraint. Specify the exact connector variant on the order and establish the mating connection separately; the box designation does not identify a lead.

The M8 form is known; the connection details are not

The connector pinout is missing, though the threaded M8 body establishes the mounting form. Get the pinout and mechanical drawing before fixing the harness and bracket; the output-load rating is also needed to finalize the controller input.

View the Win-Source product page for E2E-X1R5B1T8-M5.

Key Takeaways for Engineers & Buyers

  • Keep the target within the listed 1.5mm sensing distance; resolve target-material effects before fixing the bracket.
  • Match the 10V–30V supply range and PNP-NO output to the controller input.
  • Obtain the connector pinout before committing the harness.