1.5mm sensing distance, 10V to 30V supply limits and an M8 threaded body with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
The 1.5mm sensing distance demands a controlled gap
1.5mm is the listed sensing distance. E2E-X1R5B1TL8 2M needs a controlled metal-target position: target material and approach matter, and a wandering gap can turn detection into missed counts.
Can this cable-lead sensor stay on a running line?
Can it stay on a running line? Yes. The lifecycle signals agree on Active, supporting new design-in and existing production, with no status conflict identified. EU RoHS is listed as compliant.
The practical constraint is cable-lead termination. Set the routing and termination process for the M8 threaded sensor before committing the machine harness; a connector-based installation cannot take this part without an interface change.
The supply and response figures set different boundaries
The fit is narrow. The machine rail must fall within the listed 10V to 30V supply limits; a rail outside those bounds rules out the electrical interface even if the PNP-NO, 3-wire output matches the controller input. The listed 2kHz response frequency gives a speed figure, but it doesn’t establish that every passing target will be detected at the installed gap. Target motion and controller timing still decide whether counts are missed.
The -40°C to 85°C operating-temperature range defines the environmental window. IP67 and IP69K address ingress, not output loading. A shielded, stainless-steel M8 threaded body fits a compact machine fixture with a controlled target approach, but it does not solve a mounting hole or cable path built for a different mechanical connection.
The 1.5mm gap still needs target and mounting data
The tight gap makes the missing sensing-distance-versus-target curve decisive. The output load-current limit and wiring diagram are absent too: matching a PNP input says nothing about what the output can safely drive. The missing mounting drawing must settle clearance around the M8 body and cable exit.
View the Win-Source product page for E2E-X1R5B1TL8 2M.
Key Takeaways for Engineers & Buyers
- Set the target gap against the listed 1.5mm sensing distance.
- Match the controller input to the PNP-NO, 3-wire output.
- Plan cable-lead routing around the M8 threaded mount.