1.5mm sensing ceiling, 10V to 30V supply limits, and M8 threaded mounting define the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

Active status permits a new design-in

The 1.5mm ceiling forces a close target. E2E-X1R5B1TL8-M5 has matching Active lifecycle signals, making it a new-design candidate where that gap can be maintained. EU RoHS compliance is listed, but neither designation extends the sensing reach.

The 1.5mm reach leaves little room for placement error

1.5mm is the listed sensing-distance ceiling, not a guaranteed switching gap for every target. Placement matters. If motion or mounting variation moves the target beyond that reach, the sensor can miss it. The 2kHz response-frequency ceiling supports consideration for repeated detection, but gives neither switching delay nor assurance that a particular moving target will be caught.

A PNP-NO input and close metal target make the fit

A long sensing gap or an input that cannot use a 3-Wire PNP-NO signal rules this sensor out. It belongs near a metal target, mounted at the required gap in its shielded, threaded M8 stainless-steel body. The listed IP67 and IP69K ingress classifications help screen the installation, but neither settles how the connector will be protected in the assembled machine.

Supply limits are clear; output loading is not

Even with that mechanical fit, the electrical interface remains open. The 10V to 30V supply limits allow a check against the intended rail, but don't specify allowable ripple or output load. The stated operating-temperature range is -40°C to 85°C; installations outside it fall beyond the listed limit. These bounds narrow the choice without completing the electrical interface.

The output-load rating is missing, leaving no stated limit against which to check a controller input or connected load. The connector pinout is missing too: 3-Wire identifies the signal arrangement but doesn't tell you how to wire the mating lead. Target-dependent sensing information is needed to determine how much of the 1.5mm reach applies to the actual installation, while switching-delay data is needed to assess timing beyond the 2kHz response-frequency ceiling.

M8 mounting is not the whole purchase specification

M8 identifies the threaded body, but termination is listed only as Connector and packaging as Box. Put the mating-connector requirement on the assembly BOM before ordering; a sensor that mounts but cannot be connected still stops the line.

View the Win-Source product page for E2E-X1R5B1TL8-M5.

Key Takeaways for Engineers & Buyers

  • Check the target gap against the 1.5mm sensing ceiling.
  • Match the controller input to the 3-Wire PNP-NO output.
  • Hold mating-connector selection until the pinout is in hand.