1.5mm sensing distance, 10V to 30V supply limits, threaded M8 body, -40°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
Active status helps, but the target must come close
The 1.5mm sensing distance leaves little margin for a wandering target. Even so, E2E-X1R5B2L8 2M is an Active candidate for new industrial designs that can hold that gap. The lifecycle signals agree, and EU RoHS compliance is listed. Neither changes the geometry: establish the target path before committing to the threaded M8 mount.
An M8 inductive sensor for close targets, not every input
This part is wrong for a controller expecting an NPN or normally open signal. Its PNP-NC, 3-Wire output needs a matching input; a logic mismatch can make a missed target look like a detected one. The listed 1.5mm sensing distance also rules out a target path that cannot be held close to the sensor face.
The shielded stainless-steel M8 body gives a compact threaded mount, while IP67 and IP69K are the listed ingress ratings to weigh against the sensor’s position in the enclosure. The -40°C to 85°C operating-temperature range sets the ambient boundary for that placement. A 2kHz response-frequency ceiling helps screen the event rate, but it does not, by itself, establish reliable detection of a moving target.
The supply window does not rate the output load
30V is the listed supply ceiling. The 10V lower limit rules out rails below it; neither bound specifies the load the PNP-NC output can drive. Don't read the supply range as an output-current rating.
Is this the cable-lead build the line needs?
How does it connect? This M8 sensor has cable leads, not a listed connector. Match the machine’s wiring plan to those leads before ordering the Box-packaged part. Active status supports a new build as well as existing production; it does not settle the installed termination.
What still blocks bracket and input-circuit sign-off?
The mounting drawing is absent. So are the cable-lead wiring assignment and output load-current rating. Without those details, the listed M8 thread and PNP-NC output cannot settle bracket release or controller-input sign-off.
View the Win-Source product page for E2E-X1R5B2L8 2M.
Key Takeaways for Engineers & Buyers
- Check target clearance against the 1.5mm sensing distance.
- Match the controller input to the PNP-NC, 3-Wire output.
- Specify cable leads on the M8 machine drawing before release.