1.5mm sensing distance, M8 thread and 10V to 30V supply bounds set the fit.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V |
The M8 body needs a close, repeatable target
A target that cannot pass close to the sensing face is the wrong job for this sensor. The listed 1.5mm sensing distance suits repeatable metal-target positioning, not uncertain target travel. With its shielded, stainless-steel M8 threaded body, E2E-X1R5C1L8 5M belongs in a machine bracket that lets the sensing face be positioned deliberately and held there. The NPN-NO, 3-wire output must match the input circuit; it isn't a generic switch contact.
Lifecycle signals agree on Active, supporting new design-in. EU RoHS compliance is listed, though no directive revision is specified. IP67 and IP69K support considering exposed industrial installations, but the installed cable termination still needs attention for a particular washdown arrangement.
The 2kHz ceiling does not settle switching timing
The 2kHz response-frequency ceiling doesn't specify switching delay for a moving target. The firmer electrical boundary is the listed 10V to 30V supply range, though it says nothing about permitted output loading.
NPN-NO still leaves the input interface unresolved
That missing load limit matters. Without an output load-current rating, NPN-NO alone cannot settle the input interface. The absent wiring diagram and mounting drawing also leave the cable-lead wiring and threaded mounting arrangement unresolved; the package description cannot stand in for either.
Cable routing is the repeat-build constraint
Temperature is bounded by the -40°C to 85°C operating range; cable routing still needs a repeatable path. For E2E-X1R5C1L8 5M, box packaging and cable leads call for a defined cable exit and strain-relief arrangement on the assembly drawing. Set that route before releasing a running line. A changed path can turn the same threaded sensor installation into rework.
View the Win-Source product page for E2E-X1R5C1L8 5M.
Key Takeaways for Engineers & Buyers
- Set target clearance against the listed 1.5mm sensing distance.
- Keep the supply within the listed 10V to 30V bounds.
- Match the NPN-NO input and obtain the missing output load-current rating.