1.5mm sensing distance, 10V ~ 30V supply limits, and threaded M8 mounting set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

Active status supports a new M8 sensor installation

Is this sensor still active for a new machine build? Yes. Omron lists E2E-X1R5C1L8-M3 as Active across its lifecycle fields and marks it compliant with EU RoHS. The connector termination needs attention before the build is released: specify the mating connection, or assembly stops at the sensor interface. The Box package designation doesn't identify that connection.

The 1.5mm sensing distance puts target placement first

1.5mm is the listed sensing distance for E2E-X1R5C1L8-M3. A closely positioned metal target is plausible; detection across an unspecified gap or for every target material isn't established. Shielded construction matters to the mounting choice, but it does not settle how nearby metal affects the installed sensor. If the mechanism cannot hold the target in position, the electrical fit is beside the point.

M8 mounting must work with the NPN input and supply limits

Input compatibility is the electrical constraint: the 10V ~ 30V supply range comes with an NPN-NO, 3-wire output, so the controller input must accept that switching polarity. Those voltage limits do not establish an output load-current limit. A sensor that fits the hole cannot fix the wrong input topology.

The threaded M8 stainless-steel body mounts E2E-X1R5C1L8-M3 on the machine, with its connector at the sensing location. IP67 and IP69K are the listed ingress-protection ratings; neither establishes the sealing of the assembled connector. The -40°C ~ 85°C operating temperature range defines the sensor’s stated environmental fit, not the temperature tolerance of the mating connection or surrounding equipment.

2kHz leaves switching and installation details open

2kHz is the listed response frequency, not a switching-delay specification for a moving target. The datasheet still needs to supply switching timing, the connector pinout, and the mounting drawing before the control input and bracket can be released.

View the Win-Source product page for E2E-X1R5C1L8-M3.

Key Takeaways for Engineers & Buyers

  • Check target placement against the listed 1.5mm sensing distance.
  • Match the NPN-NO, 3-wire output to the machine input.