Omron E2E-X1R5C28-M3: Active for new machine designs

E2E-X1R5C28-M3 Omron product image

1.5mm sensing, 10V ~ 30V supply, threaded M8 body and -40°C ~ 85°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 30V

A short reach, but an Active part for new machines

The short reach is the catch. A listed 1.5mm sensing distance leaves little room for uncertain target position and does not establish reliable detection at every point within that distance. E2E-X1R5C28-M3 is Active, making it a reasonable new-design choice where the target can be positioned closely. Its threaded M8 body suits a compact machine fixture, and the shielded construction gives the designer a defined mounting feature. EU RoHS compliance is listed.

Will the specified M8 sensor arrive with the right termination?

Will the sensor arrive with a connector termination? Specify that and the threaded M8 body on the purchase line. The listed package is a Box; it describes how the part is packed, not how it connects to the machine. A generic inductive-sensor callout could leave the assembly team with the wrong termination.

The 1.5mm reach sets the fixture, not just the sensor choice

This part is wrong for a target that cannot be held within the listed 1.5mm sensing distance or a controller expecting something other than an NPN-NC, 3-wire output. In a close-positioned metal-detection station, the sensing face must reach the target and the controller must accept that output, or the station may miss the target or report the wrong state.

The listed 10V ~ 30V supply range bounds the rail choice; operation outside it is not specified. The listed 2kHz response-frequency figure is a limit, not a proven machine-cycle rate. It can't settle the timing decision without the sensor’s switching behavior under the intended target conditions.

IP67 and IP69K do not settle the mounting environment

That close positioning puts the housing near whatever reaches the fixture. IP67 and IP69K are listed ingress-protection ratings, but they don't establish compatibility with a particular process fluid. The -40°C ~ 85°C operating-temperature range bounds sensor placement; it does not tell you the temperature at the sensing face inside a heated fixture.

The missing curves and drawing decide the final fit

1.5mm makes the missing target-material sensing curves consequential. A connector pinout and mechanical drawing are also absent. Those items are needed to settle detection against the actual target, controller wiring and mounting depth before the fixture is fixed.

View the Win-Source product page for E2E-X1R5C28-M3.

Key Takeaways for Engineers & Buyers

  • Check target clearance against the listed 1.5mm sensing distance.
  • Match the controller input to the NPN-NC, 3-wire output.
  • Specify the connector-terminated M8 body on the purchase line.