Omron E2E-X1R5F1-M3: Discontinued, Sustaining Only

E2E-X1R5F1-M3 Omron product image

1.5mm sensing distance, 10V ~ 40V supply bounds and M8 thread; not for new design-in.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR PROX INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 40V

The 1.5mm reach puts the bracket under scrutiny

1.5mm is the listed sensing distance. Target position and bracket movement matter before the threaded M8 body earns a place in the machine. The listed 10V ~ 40V supply bounds can screen out a mismatched control rail, but they do not establish what happens during rail transients or how much current the PNP output can drive. The 2kHz response-frequency figure helps screen event rate; it does not establish detection of a moving target at every installed gap.

Discontinued status settles the buying decision

Don't design it in. Lifecycle Status and Product Status both say Discontinued; another lifecycle signal says EOL. Neither supports a new E2E-X1R5F1-M3 design-in. For existing production, secure inventory and plan migration. Bulk packaging calls for matching receiving and line handling to the established build rather than assuming individual packaging.

The -40°C ~ 85°C operating-temperature range is a listed boundary for the installed sensor, not evidence that a hot enclosure has headroom. Check the temperature at the mounting point before keeping this part on a running line. EU RoHS compliance is stated; it does not change the lifecycle decision.

A normally closed input rules out a direct fit

Wrong for a controller input that expects normally closed switching: this sensor's output is PNP-NO, 3-Wire. In existing equipment built around a connector-terminated, shielded M8 inductive sensor, the form is worth checking. Its IP67 rating does not settle sealing at the installed connector.

The M8 thread still leaves the connection unresolved

The missing connector pinout is the weak point: connector termination is stated, but cable mating remains open. The threaded M8 body narrows the mounting question, though a mechanical drawing is absent. Those are concrete checks for sustaining use, not grounds to release a bracket or cable change. The output load-current limit is also absent, so the PNP-NO interface cannot be cleared electrically from these specifications.

View the Win-Source product page for E2E-X1R5F1-M3.

Key Takeaways for Engineers & Buyers

  • Check the 1.5mm sensing distance against installed target travel.
  • Match the PNP-NO, 3-Wire output to the controller input.
  • For discontinued E2E-X1R5F1-M3, secure inventory for existing production and plan migration.