Omron E2E-X1R5F2 5M: Discontinued, Sustaining Only

E2E-X1R5F2 5M Omron product image

1.5mm sensing distance, 10V ~ 40V supply, M8 thread; discontinued for new designs.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR PROX INDUCT 1.
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 40V

Discontinued status rules out a new sensor design-in

No new design-in. E2E-X1R5F2 5M is marked Discontinued in both lifecycle and product status, while another lifecycle field says EOL. Keep it on sustaining designs while planning migration.

The compliance records disagree too: one says RoHS Compliant and another says RoHS Non-Compliant. EU RoHS status is unresolved, not cleared.

Can an existing line keep this bulk-packed sensor?

Can the next build still use this sensor? Yes, for existing production, but it's discontinued. Secure inventory and plan migration; bulk packaging doesn't change the wired, threaded installation.

The 1.5mm target gap decides the mechanical fit

And that migration starts at the target, not the controller. The listed 1.5mm sensing distance constrains target clearance at the shielded inductive face, but it does not establish detection with a different target material or mounting arrangement. The M8 threaded cylinder belongs in a machine fixture, with cable leads carrying its PNP-NC, 3-Wire signal to a compatible input. A controller expecting a different output state is not a direct fit.

The 10V ~ 40V supply is an operating range; a rail outside it rules out this sensor before response speed matters. The -40°C ~ 85°C operating range bounds the stated temperature fit but does not establish sensing behavior throughout that range. The listed 2kHz response frequency is a ceiling, not a promised switching speed in the installed machine; faster events cannot be justified from that figure.

The M8 fixture and cable still need drawings and wiring data

A 1.5mm reach on an M8 thread leaves little room for unchecked fixture clearance. No mechanical drawing settles mounting clearances; the cable-lead pinout and output-load-current rating are also absent, blocking fixture and wiring release.

View the Win-Source product page for E2E-X1R5F2 5M.

Key Takeaways for Engineers & Buyers

  • Check target clearance against the listed 1.5mm sensing distance.
  • Match the 10V ~ 40V supply and PNP-NC, 3-Wire output to the controller.
  • Resolve the conflicting RoHS records before releasing sustaining builds.