1.5mm sensing distance, 10V ~ 40V supply limits and a threaded M8 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR PROX INDUCT 1. |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2kHz; Voltage - Supply: 10V ~ 40V |
Discontinued status decides the design-in question
The design-in constraint is availability, not the 1.5mm reach. One lifecycle signal says EOL; the lifecycle and product status fields say Discontinued. Both rule out new design-in. Use the part only to sustain existing production while planning migration. It is EU RoHS compliant.
The 1.5mm reach leaves little room for target position
1.5mm is the listed sensing distance. Check it against the target’s installed position, especially where the target can move away from the sensor. The shielded, threaded M8 body suits a compact mounted sensing point. It won't make a poorly positioned target detectable.
The 2kHz response-frequency figure helps screen moving-target applications, but it does not establish detection at a particular target width or speed.
The supply bounds do not settle the control input
10V ~ 40V marks the listed supply bounds, not a selected operating rail or a claim of transient tolerance. Check the machine rail against both bounds before carrying this sensor into existing wiring, and confirm that its PNP-NC, 3-Wire output matches the input’s expected polarity. A voltage match alone does not settle the signal behavior.
The -40°C ~ 85°C operating-temperature range and IP67 rating help define the installation envelope. Neither establishes how the connector assembly performs once mounted.
The connector details decide whether a running line can keep it
Even with the supply and input settled, an apparent mechanical fit can fail at the connector. The part has a listed connector termination and bulk packaging, but no pinout or mating-connector drawing. Obtain both before changing the wiring on a sustaining line. The threaded M8 body doesn't identify the electrical connection.
Sensing-distance behavior across target materials and the output load-current limit remain concrete gaps: the first determines whether the actual target stays detectable at the installed gap, while the second determines whether the PNP-NC output can drive the existing input without exceeding its limit.
View the Win-Source product page for E2E-X1R5F2-M3.
Key Takeaways for Engineers & Buyers
- Keep E2E-X1R5F2-M3 off new BOMs; plan migration for existing production.
- Check target clearance against the listed 1.5mm sensing distance.
- Get the connector pinout before wiring the PNP-NC, 3-Wire output.