Omron E2E-X1R5Y1 5M: Discontinued, Sustaining Only

E2E-X1R5Y1 5M Omron product image

1.5mm sensing distance, 20 VAC ~ 264 VAC supply limits, M8 threaded body; discontinued.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M8
Core functionSENSOR PROX INDUCT 1.
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC

The short reach is workable; the lifecycle stops new design-in

Close target placement is the constraint imposed by the 1.5mm reach. Lifecycle is the harder stop: E2E-X1R5Y1 5M is for sustaining designs only. An EOL signal and two Discontinued statuses differ in wording, not outcome. It is listed as EU RoHS compliant.

A 1.5mm target gap puts the fixture under scrutiny

1.5mm is the listed sensing-distance ceiling, not a promise that every metal target will switch at that gap. Target approach and fixture repeatability determine whether the machine registers a pass. A wandering target can miss even when the electrical connection remains intact.

The 20 VAC ~ 264 VAC supply limits rule out a DC rail. Treat that range as a screen, not a preferred working setpoint. SCR-NO, 2-wire isn't a dry contact or a transistor output; it is a specific switching interface. Match it to the receiving input before wiring the machine, because a mismatch can leave the input asserted or prevent it from registering a target.

25Hz screens the event rate, not the switching waveform

25Hz is the listed response frequency. It screens the machine's event rate but does not establish detection of brief passing targets. The -25°C ~ 70°C operating-temperature range defines the stated environmental fit; operation outside it is not established here.

The M8 threaded stainless-steel cylinder has IP67 ingress protection and suits a compact, exposed machine mounting point. Its shielded inductive construction belongs beside a close metal target, not at a long standoff.

An M8 body match cannot settle wiring or mounting

A cable-for-cable swap is wrong for an SCR-NO, 2-wire sensor until its connections are known. The datasheet still has to supply the pinout and mounting drawing. It also needs the output current limit and off-state leakage. Those details determine whether the load stays within the output's limit, whether the receiving input stays off when it should, and whether the cable clears the fixture. None is specified here.

Can this discontinued sensor keep an existing line running?

Can we keep the existing line running? For E2E-X1R5Y1 5M, that is a sustaining-production question, not a reason to start another design. Bulk packaging and cable-lead termination put harness preparation in the receiving check; an M8 body match alone won't keep an assembly step unchanged. Secure inventory for existing production and plan migration before a harness change interrupts the line.

View the Win-Source product page for E2E-X1R5Y1 5M.

Key Takeaways for Engineers & Buyers

  • Check target placement against the listed 1.5mm sensing distance.
  • Match the SCR-NO, 2-wire output to the receiving input circuit.
  • Secure inventory for existing production and plan migration.