1.5mm sensing distance, 20 VAC ~ 264 VAC supply, M8 threaded body; discontinued.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M8 |
| Core function | SENSOR PROX INDUCT 1. |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
Keep this Omron sensor off new BOMs
Don't design this in. An EOL signal conflicts with fields marked Discontinued, but neither supports a new design. Keep E2E-X1R5Y2 in existing production while securing inventory and planning migration.
It ships in bulk with cable leads, so keep the running line's cable-preparation and handling instructions. It is EU RoHS compliant; no revision is specified.
The 1.5mm gap matters more than the broad AC range
The listed 1.5mm sensing distance leaves little room for a loose target path. The 20 VAC ~ 264 VAC supply range gives an AC control circuit a defined window, but says nothing about the load the output can drive. Treat 264 VAC as the supply ceiling, not a working setpoint.
That 1.5mm figure can rule out a machine with a larger or variable target gap. It cannot, by itself, settle detection of a particular target material.
An M8 body fits only if the wiring does too
A plug-in DC-input sensor position is wrong for this AC-supplied, SCR-NC, 2-Wire device. It can fit an existing circuit expecting that output, provided the target path stays within the listed 1.5mm sensing distance. A matching thread alone will not save a line whose input expects different switching behavior.
The M8 threaded cylinder and cable leads call for a mounted, hard-wired installation, not a connector swap. Its shielded inductive construction suits close metal-target detection, while the IP67 rating addresses ingress protection rather than the details of the cable exit. The stated operating range is -25°C ~ 70°C; an installation outside it is out of bounds, and the listing does not establish how the cable should be routed at either extreme.
The 25Hz figure cannot close the wiring check
25Hz is the listed response frequency, not a switching waveform or a promise about target speed. Output load rating and off-state leakage are absent, leaving input switching reliability unresolved. The missing mounting drawing leaves the M8 mechanical swap unsettled.
View the Win-Source product page for E2E-X1R5Y2.
Key Takeaways for Engineers & Buyers
- Check the target path against the listed 1.5mm sensing distance.
- Match the existing input to the SCR-NC, 2-Wire output.
- Secure inventory for discontinued production and schedule migration.