Sensing distance and supply voltage unstated; bulk industrial proximity sensor with conflicting EU RoHS entries.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Core function | SENSOR PROX |
Active status does not clear the RoHS conflict
No sensing-distance figure means the target gap can't be checked. E2E-X20D230-TR 2M is marked Active in every lifecycle field and remains a candidate for new design-in and sustaining designs, but that status says nothing about detection at the installed distance. The missing limit blocks a check against the machine layout.
The compliance entries also disagree. One says EU RoHS compliant; the product specification says RoHS Non-Compliant. Hold compliance approval until Omron resolves the conflict. Neither entry settles it.
Does 2M establish how this sensor connects?
2M appears in the order code, but no cable length or termination style is specified. Don't turn the suffix into a wiring dimension. The sensing distance, output type, supply-voltage range and termination style are still needed to fix the sensor position and connect it to an input. No operating-temperature limit is stated, so ambient suitability remains open. These are selection questions, not margins to estimate from the part number.
Bulk packing sets the receiving plan
Bulk packing needs a plan. Receiving and line-side handling need to account for that stated packaging format before the order for E2E-X20D230-TR 2M is released. Active status says nothing about how the parts arrive at the assembly station.
An unspecified sensing distance leaves the station open
Wrong for a locked sensor position: the sensing-distance limit is unstated. It remains an early candidate for an industrial proximity sensor station, not a released station drawing, until the distance and electrical interface are established.
View the Win-Source product page for E2E-X20D230-TR 2M.
Key Takeaways for Engineers & Buyers
- Hold EU RoHS approval until Omron resolves the conflicting entries.
- Get the sensing distance and output type before assigning a sensor station.
- Plan receiving and line-side handling for bulk packaging.