Omron E2E-X20MB1DL18 5M: Active for New Designs

E2E-X20MB1DL18 5M Omron product image

20mm sensing distance, 10V to 30V supply bounds, M18 body and -25°C to 70°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR INDUCT 20MM PNP M18 NO
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V

Does the 20mm reach work in this M18 mounting?

20mm is the listed sensing distance. It does not guarantee pickup across every metal target or mounting arrangement. For E2E-X20MB1DL18 5M, that reach supports new design-in where the M18 threaded body fits and target position can be checked in the actual assembly, but it doesn't settle bracket geometry.

The listed 10V to 30V supply bounds help establish whether the control rail is suitable, though they do not establish switching behavior at either boundary. The PNP-NO, 3-wire output must match the input circuit; a correctly positioned sensor can still deliver the wrong signal. The part is listed Active.

Unshielded mounting limits the value of the ingress ratings

Unshielded construction complicates close metal mounting. IP67 and IP69K make a stronger case for this nickel-plated brass sensor in a wet industrial location, but neither rating settles mounting clearance or chemical exposure.

A 200Hz ceiling rules out faster detection

Events that outrun the listed 200Hz response-frequency ceiling are wrong for this sensor. It belongs on slower metal-presence checks where the control sequence can tolerate that limit. The -25°C to 70°C operating range bounds the temperature decision.

The listing lacks a target-dependent sensing curve and mounting-clearance drawing. It also lacks an output-load limit and wiring pinout. Those items are needed before fixing the bracket and input-card connection.

Will the cable-lead version fit the assembly?

Cable leads or a connector? E2E-X20MB1DL18 5M is packaged as a Box and specified with cable leads, not a connector. Put that termination on the BOM so the assembly is built around the specified part. EU RoHS compliance is listed.

View the Win-Source product page for E2E-X20MB1DL18 5M.

Key Takeaways for Engineers & Buyers

  • Check 20mm pickup against the actual metal target and mounting geometry.
  • Match the 10V to 30V supply bounds and PNP-NO, 3-wire output to the input circuit.
  • Put the cable-lead termination on the BOM before releasing the assembly.